MOUNTING INSTRUCTIONS

Mounting

VALLOX 90 MC has to be mounted in 

a place where temperature does not 

go below +10 °C.  Without protective 

enclosure, the unit must be located in 

a place with no acoustic disturbance: 

storerooms, technical rooms etc.

Wall mounting

VALLOX 90 MC is mounted on the wall 

with a mounting plate as shown in the 

adjacent fi gure.

Wall construction

Observe the wall construction during 

mounting. Avoid mounting the unit on 

a hollow, echoing dividing wall and 

on a bedroom wall because of sound 

conduction, or prevent sound conduction.

Condensing water

The delivery includes a water seal. By 

connecting a pipe to the water seal the 

water condensing from extract air can be 

led to a fl oor drain (not directly to the drain). 

The pipe must not rise after the water seal. 

The unit has to be mounted horizontally 

level, so that condensing water can get out 

of the unit.

597

689

151

24

172

483

205

During mounting, the unit rises 
10 mm higher than the fi nal height.

The lead-in of electric wires 
can be done from both sides 
of the unit.

Wall mounting plate

BOTTOM EDGE 
OF BRACKET

Vallox Silent Klick 

water seal

Содержание 90MC Series

Страница 1: ...LOX 90MC L Operating maintenance and technical instructions 10 1 2 8 4 5 3 11 12 6 7 9 Electrical connection 230 V 50 Hz 5 7 A Degree of protection provided by enclosures IP34 Fans Extract air 0 119 k...

Страница 2: ...r fan during the time when the fireplace is lighted NOTE The starting of the extract air fan may weaken draught in the fireplace In winter this situation may disturb the winter function of the unit Th...

Страница 3: ...he unit with two kinds of filters A coarse filter A filters off insects heavy pollen and other dust An F7 class fine filter B filters off fine dust invisible to the eye Extract air is filtered with a...

Страница 4: ...y disconnect the quick coupling of the fan conductor Detaching extract air filter B The fan is attached to the fixing plate with a butter y nut Detach the butter y nuts and lift the fan out Finally di...

Страница 5: ...m3 s At a lower total pressure SFP will be smaller at this speed Sound values Sound power level from the ventilation unit to supply air ducts by octave band LW dB Sound power level from the ventilatio...

Страница 6: ...Fault signal relay output 7023000 TECHNICAL DATA 1 2 3 4 5 6 7 8 9 1 2 3 4 5 LINE NEUTRAL SLI SNI SLO SNO SFL SFN EFL EFN FSO FSI AHL AHN PHL PHN 230V 50Hz BL1 BL BN E I E O 12 34 LED 90 C 130 C R1 T...

Страница 7: ...onstruction during mounting Avoid mounting the unit on a hollow echoing dividing wall and on a bedroom wall because of sound conduction or prevent sound conduction Condensing water The delivery includ...

Страница 8: ...a thread bar from the lower surface of the ceiling is the space between the lower surface of the ceiling and the lower surface of the ceiling mounting plate 25 mm Mounting of ventilation unit to ceil...

Отзывы: