© VALLOX • We reserve the right to make changes without prior notice.

What the units include can vary depending on the sales area.

LINE:        Phase voltage
NEUTRAL:  Zero voltage
SLI:      

Phase voltage to safety switch

SNI:      

Zero voltage to safety switch

SLO:       Phase voltage to circuit board from safety switch
SNO:       Zero voltage to circuit board from safety switch
SNO:       Phase voltage to supply air fan
SFN:       Zero voltage to supply air fan
EFL:      

Phase voltage to extract air fan

EFN:       Zero voltage to extract air fan
FSO:       Input to fireplace switch
FSI:      

Fireplace switch output

AHL:       Phase voltage to post-heating
AHN:       Zero voltage to post-heating
PHL:      

Phase voltage to additional heater

PHN:       Zero voltage to additional heater
BL:     

Damper motor phase A

BL1:      

Damper motor phase B

BN:      

Zero voltage to damper motor

E/I:      

Input voltage to fault signal relay

E/O:      Fault signal relay output

7023000

TECHNICAL DATA

1

2

3

4

5

6

7

8

9

1
2

3
4
5

LINE

NEUTRAL

SLI

SNI

SLO

SNO

SFL

SFN

EFL

EFN

FSO

FSI

AHL
AHN

PHL

PHN

230V 50Hz

BL1

BL

BN

E/I

E/O

1 2 3 4

LED

90

ϒ

C

130

ϒ

C

R1

T1

T2

M

1 2 3 4

LED

-

+

S

DIP switch

Up

Down

1. Post-heating

Electric

VKL

2. Additional heating Electric

MLV

3. Unit type

Bypass

Input fan stopped

4. Not in use

Not to be used

Selected

Electrical diagram

Fireplace switch

Safety/door switch 

Protective ground  

to a separate block

Programming  

connector 

9. GND / -
8. Supply fan PWM
7. Supply fan Tako
6. GND / -
5. Extract fan PWM
4. Extract fan Tako
3. GND / -
2. 11.2 Vdc /+
1 Control signal S

Extract air NTC 
Outdoor air NTC 
Supply air to the dwelling NTC 
Exhaust air NTC 
Supply air from the cell NTC 

Adjustment of freezing level

PWM level adjustment

DIP switch

Adjustment of post-heating

External controller or cooker hood

An external 0–10 Vdc voltage input can be introduced between 

S and GND for fan control.

Supply air 

fan

Extract air 

fan

Post-heating 

electric radiator 

900 W

Belimo damper motor 230 VAC

Содержание 90MC Series

Страница 1: ...LOX 90MC L Operating maintenance and technical instructions 10 1 2 8 4 5 3 11 12 6 7 9 Electrical connection 230 V 50 Hz 5 7 A Degree of protection provided by enclosures IP34 Fans Extract air 0 119 k...

Страница 2: ...r fan during the time when the fireplace is lighted NOTE The starting of the extract air fan may weaken draught in the fireplace In winter this situation may disturb the winter function of the unit Th...

Страница 3: ...he unit with two kinds of filters A coarse filter A filters off insects heavy pollen and other dust An F7 class fine filter B filters off fine dust invisible to the eye Extract air is filtered with a...

Страница 4: ...y disconnect the quick coupling of the fan conductor Detaching extract air filter B The fan is attached to the fixing plate with a butter y nut Detach the butter y nuts and lift the fan out Finally di...

Страница 5: ...m3 s At a lower total pressure SFP will be smaller at this speed Sound values Sound power level from the ventilation unit to supply air ducts by octave band LW dB Sound power level from the ventilatio...

Страница 6: ...Fault signal relay output 7023000 TECHNICAL DATA 1 2 3 4 5 6 7 8 9 1 2 3 4 5 LINE NEUTRAL SLI SNI SLO SNO SFL SFN EFL EFN FSO FSI AHL AHN PHL PHN 230V 50Hz BL1 BL BN E I E O 12 34 LED 90 C 130 C R1 T...

Страница 7: ...onstruction during mounting Avoid mounting the unit on a hollow echoing dividing wall and on a bedroom wall because of sound conduction or prevent sound conduction Condensing water The delivery includ...

Страница 8: ...a thread bar from the lower surface of the ceiling is the space between the lower surface of the ceiling and the lower surface of the ceiling mounting plate 25 mm Mounting of ventilation unit to ceil...

Отзывы: