Vallox 90MC Series Скачать руководство пользователя страница 5

5

Vallox

90

MC

© VALLOX • We reserve the right to make changes without prior notice.
What the units include can vary depending on the sales area.

Dimensions and duct outlets

Measuring points

Measuring points after the connection 

outlet. Fan curves indicate the total pressure 

available for duct losses.

Input powers of fans

Fan control 

voltage 

V

Combined input 

power of fans 

W

3.3

9

4.4

15

5.0

22

5.7

31

6.6

47

7.7

72

8.8

114

11.2

182

TECHNICAL DATA

597

689

151

24

172

Room required by 

VALLOX Silent Klick 

water seal.

70 mm

Duct outlets

Inner diameter of female outlet 

collar ø125
1.  Supply air to the dwelling 
2.  Extract air from the dwelling 

 

to the unit

3.  Outdoor air to the unit
4.  Exhaust air out

MODEL  L

MODEL  R

Extract air

Supply air

E

S

Supply/extract air fl ows

T = Supply air, fan speed 1…8              
P = Extract air, fan speed 1…8

Pressure loss in ducts. T

otal pressure Pa

Volume fl ow rate

dm

3

/s

SFP =

Input power (total) (W)

Air fl ow (max.) (dm

3

/s)

SFP (Specifi c Fan Power) recommended value <2.5 (kW m

3

/s)

At a lower total pressure, SFP will be smaller at this speed.

Sound values 

Sound power level from the ventilation unit 

to supply air ducts by octave band  L

W

, dB

Sound power level from the ventilation unit 

to extract air ducts by octave band  L

W

, dB

ADJUSTMENT POSITION/AIR FLOW 

ADJUSTMENT POSITION/AIR FLOW 

ADJUSTMENT POSITION

2

4

6

8

2

4

6

8

AIR FLOW  dm

3

/s

16.5 l/s

27.2 l/s

40.9 l/s

65.6 l/s

23.8 l/s

35.8 l/s

51.9 l/s

76.7 l/s

Medium 

frequency

of the octave 

band, Hz

63

61.7

67.2

73.1

82.1

56.9

63.9

69.6

75.6

125

46.9

56.2

64.3

73.4

46.4

53.9

60.8

69.1

250

39.6

47.0

54.4

63.5

39.5

44.6

52.2

61.0

500

35.1

41.6

18.6

57.3

32.7

38.8

45.6

53.3

1000

31.1

38.7

45.7

52.4

27.9

35.5

43.2

48.9

2000

13.0

25.7

34.4

52.0

17.6

24.5

33.6

42.9

4000

15.6

27.5

42.0

13.3

23.2

33.8

8000

20.0

36.0

L

W

,dB 

L

WA

, dB(A)

61.8

67.6

73.7

77

57.4

64.3

70.2

76.7

38.5

46.1

53.3

59

36.4

43.5

50.5

58.2

A-weighted sound pressure level dB (A) coming from the 

unit through the envelope in the rooms where the unit 

has been installed (10 m

2

 sound absorption)

Vallox 90 MC

ADJUSTMENT POSITION/AIR FLOWS (supply/extract) 

2

4

6

8

17/24 l/s 29/39 l/s 44/56 l/s 69/81 l/s

L

pA

, dB (A)

23.9

30.6

38.0

45.3

Содержание 90MC Series

Страница 1: ...LOX 90MC L Operating maintenance and technical instructions 10 1 2 8 4 5 3 11 12 6 7 9 Electrical connection 230 V 50 Hz 5 7 A Degree of protection provided by enclosures IP34 Fans Extract air 0 119 k...

Страница 2: ...r fan during the time when the fireplace is lighted NOTE The starting of the extract air fan may weaken draught in the fireplace In winter this situation may disturb the winter function of the unit Th...

Страница 3: ...he unit with two kinds of filters A coarse filter A filters off insects heavy pollen and other dust An F7 class fine filter B filters off fine dust invisible to the eye Extract air is filtered with a...

Страница 4: ...y disconnect the quick coupling of the fan conductor Detaching extract air filter B The fan is attached to the fixing plate with a butter y nut Detach the butter y nuts and lift the fan out Finally di...

Страница 5: ...m3 s At a lower total pressure SFP will be smaller at this speed Sound values Sound power level from the ventilation unit to supply air ducts by octave band LW dB Sound power level from the ventilatio...

Страница 6: ...Fault signal relay output 7023000 TECHNICAL DATA 1 2 3 4 5 6 7 8 9 1 2 3 4 5 LINE NEUTRAL SLI SNI SLO SNO SFL SFN EFL EFN FSO FSI AHL AHN PHL PHN 230V 50Hz BL1 BL BN E I E O 12 34 LED 90 C 130 C R1 T...

Страница 7: ...onstruction during mounting Avoid mounting the unit on a hollow echoing dividing wall and on a bedroom wall because of sound conduction or prevent sound conduction Condensing water The delivery includ...

Страница 8: ...a thread bar from the lower surface of the ceiling is the space between the lower surface of the ceiling and the lower surface of the ceiling mounting plate 25 mm Mounting of ventilation unit to ceil...

Отзывы: