Low-energy ventilation unit 

with heat recovery

© Vallox
1.09.420 E
14.5.2013

Vallox

90

MC

Extract air fan 

Supply air fan

Post-heating radiator 

 

(electric 900 W)

Heat recovery cell

Outdoor air fi lter F7

Outdoor air fi lter G4

Extract air fi lter G4

Automatic summer/winter 

 damper

Safety switch

10  Measurement outlets 

 

(behind an opening door)

11  Adjustment of the relationship 

 

between supply and extract air

12  Adjustment of supply air 

 

temperature and summer/winter 

 function
13  Speed selector switch (1-4)

 (option)

13

Code 

3523

Models

VALLOX 90MC R

VALLOX 90MC L

Operating, maintenance and technical instructions

10

1

2

8

4

5

3

11
12

6

7

9

Electrical connection  

230 V 50 Hz = 5.7 A

Degree of protection provided by enclosures  IP34
Fans 

Extract air 

0.119 kW 0.9 A 92 dm

3

/s 50 Pa

direct current (DC)  Supply air 

0.119 kW 0.9 A 75 dm

3

/s 50 Pa

Heat recovery  

 

Cross-counter fl ow heat recovery cell, 

> 80%

Heat recovery bypass 

Automatic

Electric post-heating unit 

900 W, 3.9 A

Fans 

Supply air 

G4 and F7

 

Extract air 

G4

Weight 

 

52 kg

Ventilation control   

Simple Control controller (option)

 

 

PTXPA Slim-Line SC cooker hood (option)

 

 

Fireplace switch (option)

Technical data

The fi gure shows the R model

The measurement outlets are 

located behind the machine 

plate. Detach the machine 

plate by pushing it to the left 

and pull the outlets out.

Содержание 90MC Series

Страница 1: ...LOX 90MC L Operating maintenance and technical instructions 10 1 2 8 4 5 3 11 12 6 7 9 Electrical connection 230 V 50 Hz 5 7 A Degree of protection provided by enclosures IP34 Fans Extract air 0 119 k...

Страница 2: ...r fan during the time when the fireplace is lighted NOTE The starting of the extract air fan may weaken draught in the fireplace In winter this situation may disturb the winter function of the unit Th...

Страница 3: ...he unit with two kinds of filters A coarse filter A filters off insects heavy pollen and other dust An F7 class fine filter B filters off fine dust invisible to the eye Extract air is filtered with a...

Страница 4: ...y disconnect the quick coupling of the fan conductor Detaching extract air filter B The fan is attached to the fixing plate with a butter y nut Detach the butter y nuts and lift the fan out Finally di...

Страница 5: ...m3 s At a lower total pressure SFP will be smaller at this speed Sound values Sound power level from the ventilation unit to supply air ducts by octave band LW dB Sound power level from the ventilatio...

Страница 6: ...Fault signal relay output 7023000 TECHNICAL DATA 1 2 3 4 5 6 7 8 9 1 2 3 4 5 LINE NEUTRAL SLI SNI SLO SNO SFL SFN EFL EFN FSO FSI AHL AHN PHL PHN 230V 50Hz BL1 BL BN E I E O 12 34 LED 90 C 130 C R1 T...

Страница 7: ...onstruction during mounting Avoid mounting the unit on a hollow echoing dividing wall and on a bedroom wall because of sound conduction or prevent sound conduction Condensing water The delivery includ...

Страница 8: ...a thread bar from the lower surface of the ceiling is the space between the lower surface of the ceiling and the lower surface of the ceiling mounting plate 25 mm Mounting of ventilation unit to ceil...

Отзывы: