VALLOX 252 D

OPERATING PRINCIPLE OF THE VENTILATION UNIT

2

2

Silencer

Installed above the unit

Models:
VALLOX 252 D-L
VALLOX 252 D-R

VALLOX 252 D removes contaminated air
and replaces it with filtered and heated
outdoor air.
Efficient filtering of outdoor air
(EU3 + EU7) prevents harmful particles
from entering the ductwork and the rooms
via the unit. Good filtering of extract air
(EU3 + EU5) diminishes the contamination
of the unit and ensures effective operation
of heat recovery and the extract air fans.
Clogging of the supply/extract air filters
and the ductwork can be monitored if the
unit is equipped with a pressure
difference switch.
With efficient 2-step heat recovery, most
of the heat of contaminated extract air
can be transmitted to outdoor air coming
inside. The efficiency of the heat recovery
cells is approx. 70%, or 75…80% if
supply air fan heat is taken into account.
If outdoor air does not get sufficiently
warm in the heat recovery cells, it is
possible to use an (optional) heating unit
operated by water or electricity.
The unit features an automatic heat
recovery bypass function, which
eliminates needless heating of outdoor air
in the summertime. The unit also includes
an automatic defrosting function of the
water operated post-heating unit.
The automatic defrosting of the heat
recovery cells intermittently stops the
supply air fans when the temperature of
exhaust air goes under the preset
threshold value. To avoid or to decrease
the stopping of the supply air fans, you
can heat outdoor air with an electric
preheater. If the unit is equipped with a
preheater, defrosting starts when outdoor
air temperature goes below ca. -15/-
25˚C (max./min. supply air flow).
Without preheating, defrosting starts
when outdoor air temperature falls below
ca. -5˚C.
VALLOX 252 D can be controlled with the
control panel coming with the unit (3 at
most) and with optional CO

2

 (5 at most)

and %Rh sensors (2 at most).
Fan speeds can be monitored remotely
with current or voltage signals. In case of
failures in the ventilation unit, a potential-
free relay point signal is received.
The optional VALLOX LON converter
allows remote monitoring based control of
the unit.

VALLOX 252 D-R

= EXHAUST AIR

= EXTRACT AIR

= SUPPLY AIR

= OUTDOOR AIR

Options

13

14

15

16

VALLOX 252 D-L

= OUTDOOR AIR

= SUPPLY AIR

= EXTRACT AIR

= EXHAUST AIR

Main Parts

Supply air fans

Extract air fans

Heat recovery cells

Heat recovery bypass

Supply air filter EU7

Extract air filter EU5

Extract air filter EU3

Outdoor air filter EU3

Condensing water reservoir

Condensing water outlet

Electrical connection

lead-throughs

Control panel

1

2

3

5

6

7

8

9

10

10

4

11

Post-heating unit
• Electric or water

Preheater
• Electric

Pressure difference switch

Carbon dioxide sensor

Humidity sensor

LON converter

12

17

18

12

15

3

2

9

6

1

4

5

8

13

14

10

11

7

187

220

222

1100

187

222

282

1370

220

(Door and insulation 55mm)

fl250  4pcs

610 +

16

17

18

A

B

C

D

A
B
C
D

A
B
C
D

*

 Detachable inner coupling

*

2370

665

220

220

1100

187

222

282

222

187

1000

1370

Ø 250 4 pcs

Содержание 252 D Series

Страница 1: ...0 W 1 A 2x230 W 1 A Fans Heat recovery Heat recovery bypass Preheater Electric post heating unit Water circulated post heating unit Filters Filters Manual control DIGIT control panel CO2 and RH contro...

Страница 2: ...goes under the preset threshold value To avoid or to decrease the stopping of the supply air fans you can heat outdoor air with an electric preheater If the unit is equipped with a preheater defrostin...

Страница 3: ...djusts fan speed so as to keep the carbon dioxide content in the ventilation zone below the setpoint If two or more sensors are used fan speed is adjusted in accordance with the highest measuring resu...

Страница 4: ...0 25 C The factory setting is 10 C Heat recovery cell defrosting function The defrosting function prevents the heat recovery cell from freezing thereby ensuring that ventilation works in cold periods...

Страница 5: ...setpoint and the actual temperature For instance if indoor air temperature is 25 C and the setpoint is 24 C the aim is to blow 23 C air to the ventilation zone If the temperature in the ventilation zo...

Страница 6: ...tings menu press the and buttons simultaneously In the settings menu you can change setpoints for the ventilation unit The content display shows humidity and carbon dioxide content The corresponding s...

Страница 7: ...he control panel is changed with the and buttons Two control panels cannot have the same address If control panels have the same address they will go to the bus fault state and will not operate The de...

Страница 8: ...may cause a faulty post heating function 1 3 17 Choosing post heating for the unit Radiator type electric rad Automatic or manual search of the basic humidity level The selection is done with the and...

Страница 9: ...1 3 22 Changing the setpoint for carbon dioxide adjustment CO2 setting 0900 PPM Basic fan speed 1 Maximum fan speed 8 Carbon dioxide adjustment CO2 900 ppm CO2 Basic humidity level value chosen eithe...

Страница 10: ...he doors of the ventilation unit have to be mounted 5 If the filter guard symbol appears in the main display of the control panel proceed to step 7 If it does not appear proceed to step 6 6 You can in...

Страница 11: ...is not functioning The extract air filter or the cell is clogged The initial adjustments for ventilation have not been made 1 Check the insulation of the attic ducts If the heat recovery cell has fro...

Страница 12: ...e but they can be cleaned with pressure air carefully blowing against the direction of contamination When needed replace the filters with new ones The recommended interval for filter change is one yea...

Отзывы: