402
Thermo 230 / 231 / 300 / 301 / 350
4 Technical Data
Optional Fuel Filter Heater
Heater
Thermo 230
Thermo 231
Thermo 300
Thermo 301
Thermo 350
Type
Thermo 230
Thermo 231
Thermo 300
Thermo 301
Thermo 350
Mark of conformity up to 4/03
~ S230
~ S327
~ S229
~ S328
~ S228
EC type approval number e1*2001/56*
0007*--
0010*--
0008*--
0011*--
0009*--
Heater principle
High pressure atomizer
Heating flow
KW
(kcal/h)
23
(20 000)
30
(26 000)
35
(30 000)
Fuel
Diesel / fuel oil
Fuel consumption
kg/h
2.9
3.3
3.7
Nominal voltage
V-
24
Operating voltage
V-
20 ... 28
Operating voltage
(valid for application Thermo 350.190)
V-
19 ... 28
Nominal power consumption
(without circulation pump)
W
65
110
140
Permissible operating ambient
temperature range
(heater, control unit, circulation pump)
°C
–40 ... +85
Permissible storage temperature
°C
+110 max.
Permissible operating overpressure
bar
0.4 ... 2.0
Heat exchanger capacity
l
1.8
Minimum capacity of circuit
l
25
CO
2
in exhaust at nominal voltage
Vol.-%
10 ±0.5 related to 500 m above S.L.
CO
2
in exhaust at nominal voltage
(valid for application Thermo 350.190)
Vol.-%
9.2 ... 10.1
Dimensions heater
(tolerance ± 3 mm)
mm
mm
mm
length 610
width 246
heigh 220
Weight
kg
19
Circulation pump
U 4814
Aquavent 5000
U 4854
Aquavent 5000S
U 4855
Aquavent 6000C
U4856
Aquavent 6000SC
Volume flow
I/h
5000 (against 0.2 bar) 5000 (against 0.2 bar) 6000 (against 0.4 bar) 6000 (against 0.4 bar)
Nominal voltage
V =
12 or 24
24
24
24
Operating voltage range
V =
10...14 / 20...28
20...28
20...28
20...28
Nominal power consumption
W
104
104
210
210
Dimensions
Lenght 230
Width 100
Height 103
Lenght 249
Width 100
Height 105
Lenght 226
Width 115
Height 118
Lenght 231
Width 115
Height 118
Weight
kg
2.1
2.2
2.4
2.5
Filter Heater
Nominal power consumption
W
240
Nominal voltage
V -
24
Switch-on point
C°
0.5 ± 2.5
Switch-off point
C°
5.5 ± 2.5
Содержание spheros thermo 230
Страница 70: ...memos...