302
Thermo 230 / 231 / 300 / 301 / 350
3 Functional Description
Switching thresholds for Thermo xxx Raill
3.1
Switch On
Upon switch on the operating indicator light goes on.
Combustion air fan, fuel pump and circulation pump start
operation. (If fitted and temperature is < 0 °C nozzle block
preheater is also activated).
After approximately 12 seconds (run-up time) the high
voltage igniter spark is available. Approximately 1 second
later the solenoid valve in the fuel pump opens and the
nozzle sprays fuel into the combustion chamber to be
ignited by the igniter spark. A photo control circuit
deactivates the igniter box after flame-up.
3.2
Heating Operation
After reaching operating temperature the control unit
takes over to provide controlled operation by activation
and deactivation of the burner in order to maintain a nearly
constant temperature of the heat exchanger (coolant).
The heating operation is terminated as soon as the upper
operating point is exceeded.
The heater now is in the control idle period. Heater
operation is resumed when the temperature drops below
the lower operating point.
230.040
230.056
300.124
xxx.126
300.155
350.190
Version Thermo xxx*
350.056
350.155
„VOSSLOH
“
„VOSSLOH
“
973 13A
90 162 37x
90 210 12B
Scope of delivery
thru
90 162 36A
973 13D
90 162 35A
Heater
Control device
638 59D
679 81C
987 10x
978 04x
Auxiliary heating
Upper operating point
85°C
85°C
85°C
85°C
Lower operating point
75°C
72°C
70°C
70°C
Parking heating
Preheating
Upper operating point
85°C
75°C
60°C
60°C
Lower operating point
70°C
60°C
45°C
45°C
Parking heating (economic
setting)
keeping frost-free
Upper operating point
70°C
57°C
20°C
40°C
Lower operating point
55°C
42°C
5°C
25°C
Gradient evaluation
Yes
Yes
Yes
Hysteresis adaption
Yes
Yes
Yes
Low voltage threshold
18.5V
(20 sec.)
* xxx means 230 or 300 or 350