4.

 

Remove the two screws on the controller, and then begin the wiring operation. In order to 
guarantee installation safety, we recommend the following wiring order; however, you can 
choose not to follow this order and no damage will be incurred to the controller.  

 

1.

 

Connecting to external temperature sampling interface. 

2.

 

Connecting communication cable.  

3.

 

Connecting power cable.  

WARNING! RISK OF ELECTRIC SHOCK! 

We strongly recommend that fuses or breakers be 

connected at the photovoltaic array side, load side and battery side so as to avoid electric 
shock during wiring operation or faulty operations, and make sure the fuses and breakers 
are in open state before wiring.  

WARNING! DANGER OF HIGH VOLTAGE! 

Photovoltaic arrays may product a very high open-

circuit voltage. Open the breaker or fuse before wiring, and be very careful during the wiring 
process. 

WARNING! RISK OF EXPLOSION! 

Once the battery’s positive and negative terminals 

or leads that connect to the two terminals get short-circuited, a fire or explosion will occur. 
Always be careful in operation. First connect the battery, then the load, and finally the solar 

panel. When wiring, follow the order of first ‘+’ and then ‘

-

‘. 

 

4.

 

Power on. After connecting all power wires solidly and reliably, check whether wiring is 
correct and if the positive and negative poles are reversely connected. After confirming that 
no faults exist, first close the fuse or breaker of the battery, then see whether the LED 
indicators light up and the LCD screen displays information. If the LCD screen fails to display 
information, open the fuse breaker immediately and recheck if all connections are correctly 
done. If the battery functions normally, connect the solar panel. If sunlight is intense 

Содержание MPPT 30A

Страница 1: ......

Страница 2: ...urately track the maximum power point A built in maximum power point tracking algorithm can significantly improve the energy utilisation efficiency of photovoltaic systems and raise the charging effic...

Страница 3: ...linear proportion to the temperature so as to cur the temperature rises of the controller effectively keeping the controller from being damaged by overheat Featuring a temperature compensation functi...

Страница 4: ...voltage is around 12V when charging with a conventional solar controller the solar panel s voltage will stay around 12V failing to deliver the maximum power However the MPPT controller can overcome th...

Страница 5: ...ise charging and boost charging the two of which are not carried out in a repeated manner with the former getting activated once every 30 days Boost Charging by default boost charging generally lasts...

Страница 6: ...o be maintained at full state At this stage the loads can access almost all the solar power If the loads consume more power than the solar panel could provide the controller will not be able to keep t...

Страница 7: ...d space where battery gas may accumulate WARNING DANGER OF HIGH VOLTAGE Photovoltaic arrays may produce a very high open circuit voltage Open the breaker or fuse before wiring and be very careful duri...

Страница 8: ...oltage Open the breaker or fuse before wiring and be very careful during the wiring process WARNING RISK OF EXPLOSION Once the battery s positive and negative terminals or leads that connect to the tw...

Страница 9: ...e and it s recommended that installation distance be not more than 150mm If no remote temperature sensor is connected to the controller the battery temperature value will stay at 25 C If an inverter i...

Страница 10: ...uick Flashing A cycle of 2s on off lasting for 0 1s Load overload short circuited Steady On Load functioning normally Off System operating normally Steady On System malfunctioning UP Page up increase...

Страница 11: ...day time off When no sunlight is present the solar panel voltage is lower than the light control on voltage and after a time delay the controller will switch on the load when sunlight emerges the sola...

Страница 12: ...outputting and this mode is suitable for loads which need 24 hour power supply Manual operation is effective only when the load mode is manual mode 15 and tap the Set key to switch on off the load un...

Страница 13: ...ery is reversely connected the system will not operate so as to protect the controller from being burned PHOTOVOLTAIC INPUT IDE TOO HIGH VOLTAGE PROTECTION If the voltage on the photovoltaic array inp...

Страница 14: ...nal screws firmly Check if there are any dirt nesting insects or corrosion and clean as required If the lightening arrester has lost its efficacy replace it with a new one timely to prevent the contro...

Страница 15: ...72 5mm Over voltage cut off voltage 16 0V 16 0V 16 0V 9 to 17V Equalising voltage 14 6V 14 8V 9 to 17V Boost voltage 14 4V 14 2V 14 6V 9 to 17V Floating charging voltage 13 8V 13 8V 13 8V 9 to 17V Boo...

Страница 16: ...must be followed Over voltage cut off voltage charging limit voltage equalising voltage boost voltage floating charging voltage boost return voltage Over voltage cut off voltage over voltage cut off...

Страница 17: ......

Отзывы: