background image

 

 

The controller enables users to customise the parameters according to the actual conditions, but 
parameter setting must be done under the guidance of a professional person, or else faulty 
parameter settings may render the system not able to function normally.  

TYPE OF BAT 

Battery Type 

User/flooded/sealed/gel 

Sealed 

VOLT OF SYS 

System Voltage 

12V/24V 

AUTO 

EQUALIS CHG 

Equalise Charging Voltage 

9 to 17V 

14.6V 

BOOST CHG 

Boost Charging Voltage 

9 to 17V 

14.4V 

FLOAT CHG 

Floating Charging Voltage 

9 to 17V 

13.8V 

LOW VOL RECT 

Over-discharge Recovery Voltage 

9 to 17V 

12.6V 

LOW VOL DISC 

Over-discharge Voltage 

9 to 17V 

11.0V 

 

WATERPROOF

 

Waterproof level: IP32 

 

INPUT POWER LIMITING PROTECTION 

When the solar panel power exceeds the rated power, the controller will limit the solar 
panel power under the rated power so as to prevent excessively large currents from 
damaging the controller and enter into current-limited charging.  

 

BATTERY REVERSE CONNECTION PROTECTION 

If the battery is reversely connected, the system will not operate so as to protect the 
controller from being burned.  

 

PHOTOVOLTAIC INPUT IDE TOO HIGH VOLTAGE PROTECTION 

If the voltage on the photovoltaic array input side is too high, the controller will 
automatically cut off photovoltaic input. 

 

PHOTOVOLTAIC INPUT REVERSE-CONNECTION PROTECTION 

When the photovoltaic array is reversely connected, the controller will not break down, and 
when the connection problem gets solved, normal operation will resume. 

 

LOAD OVERPOWER PROTECTION 

When the load power exceeds the rated value, the load will enter into delay protection.  

 

LOAD SHORT-CIRCUIT PROTECTION 

When the load is short-circuited, the controller can implement protection in a quick and 
timely manner and will try to switch on the load again after a time delay. This protection can 
be carried out up to 5 times a day. Users can also manually address the short circuit problem 
when finding the load is short-circuited via the abnormality codes on the system data 
analysis page.  

 

REVERSE CHARGING PROTECTION AT NIGHT

 

This protection function can effectively prevent the battery from discharging through the 
solar panel at night.  

 

TVS LIGHTING PROTECTION

 

Содержание MPPT 30A

Страница 1: ......

Страница 2: ...urately track the maximum power point A built in maximum power point tracking algorithm can significantly improve the energy utilisation efficiency of photovoltaic systems and raise the charging effic...

Страница 3: ...linear proportion to the temperature so as to cur the temperature rises of the controller effectively keeping the controller from being damaged by overheat Featuring a temperature compensation functi...

Страница 4: ...voltage is around 12V when charging with a conventional solar controller the solar panel s voltage will stay around 12V failing to deliver the maximum power However the MPPT controller can overcome th...

Страница 5: ...ise charging and boost charging the two of which are not carried out in a repeated manner with the former getting activated once every 30 days Boost Charging by default boost charging generally lasts...

Страница 6: ...o be maintained at full state At this stage the loads can access almost all the solar power If the loads consume more power than the solar panel could provide the controller will not be able to keep t...

Страница 7: ...d space where battery gas may accumulate WARNING DANGER OF HIGH VOLTAGE Photovoltaic arrays may produce a very high open circuit voltage Open the breaker or fuse before wiring and be very careful duri...

Страница 8: ...oltage Open the breaker or fuse before wiring and be very careful during the wiring process WARNING RISK OF EXPLOSION Once the battery s positive and negative terminals or leads that connect to the tw...

Страница 9: ...e and it s recommended that installation distance be not more than 150mm If no remote temperature sensor is connected to the controller the battery temperature value will stay at 25 C If an inverter i...

Страница 10: ...uick Flashing A cycle of 2s on off lasting for 0 1s Load overload short circuited Steady On Load functioning normally Off System operating normally Steady On System malfunctioning UP Page up increase...

Страница 11: ...day time off When no sunlight is present the solar panel voltage is lower than the light control on voltage and after a time delay the controller will switch on the load when sunlight emerges the sola...

Страница 12: ...outputting and this mode is suitable for loads which need 24 hour power supply Manual operation is effective only when the load mode is manual mode 15 and tap the Set key to switch on off the load un...

Страница 13: ...ery is reversely connected the system will not operate so as to protect the controller from being burned PHOTOVOLTAIC INPUT IDE TOO HIGH VOLTAGE PROTECTION If the voltage on the photovoltaic array inp...

Страница 14: ...nal screws firmly Check if there are any dirt nesting insects or corrosion and clean as required If the lightening arrester has lost its efficacy replace it with a new one timely to prevent the contro...

Страница 15: ...72 5mm Over voltage cut off voltage 16 0V 16 0V 16 0V 9 to 17V Equalising voltage 14 6V 14 8V 9 to 17V Boost voltage 14 4V 14 2V 14 6V 9 to 17V Floating charging voltage 13 8V 13 8V 13 8V 9 to 17V Boo...

Страница 16: ...must be followed Over voltage cut off voltage charging limit voltage equalising voltage boost voltage floating charging voltage boost return voltage Over voltage cut off voltage over voltage cut off...

Страница 17: ......

Отзывы: