7. General
CAUTION
If any of the original wire supplied with this unit must be replaced,
it must be replace with 18 GA. 150°C wire or its equivalent.
IMPORTANT:
Turn off gas before servicing fireplace. Have a qualified service person
perform these check-ups once a year preferably before the using of the fireplace.
• Clean burner and control compartment
• Keep the control compartment and burner area clean by vacuuming or brushing at
least twice a year.
Do not disassemble the gas control;
it contains non-replaceable components.
Attempted disassembly or repair can damage the control. Exactly follow the warnings
and the lighting instructions.
• The gas control must be replaced if it has been flooded with water. Call a
qualified service technician.
• The gas control is a safety device. It must be replaced in case of any physical
damage such as bent terminals, missing parts, stripped threads, or evidence of
exposure to excessive heat.
7.1 Fireplace cleaning
Cleaning Procedure
1. Turn off fireplace.
2. Remove the barrier screen and glass door assembly.
See
«Invisimesh Barrier and glass door removal», page 26 .
3. Remove decorative media (a clean portable shop-vac is recommended).
Vacuum burner cover areas. The control module located in the bottom front corner can also be
vacuumed off.
4. Replace decorative media.
5. Reinstall the glass door and barrier screen.
6. Ignite fireplace. See
«3.1 Lighting Instructions (Proflame II Model)»
7. If flame appears abnormal, call a service person.
• Check Vent System
• The fireplace and venting system should be inspected before initial use and at least annually by a
qualified service person. Inspect the external vent cap on a regular basis to make sure that no debris