background image

 

 

2 947100 

VoIP (Voice-over-Internet-Protocol) 
Adapters

 

 

Valcom’s VoIP adapters provide loudspeaker 
paging through the client’s LAN/WAN.

 

 

VIP-801, Networked Page Zone Extender, 
enables voice access over an IP-based 
LAN/WAN. Other VIP-801(s) will allow page 
zone extensions anywhere else on the 
network.

 

 

VIP-811, Enhanced Networked Station Port, 
connects to an FXO port, loop start trunk port, 
or dedicated analog telephone terminal 
device, and is connected to an IP-based 
LAN/WAN.

 

 

VIP-821, Enhanced Networked Trunk Port, 
allows a PBX system device or IP telephone 
adapter to be connected to a managed        
IP-based LAN/WAN.  The PBX system device 
or IP telephone adapter must provide an open 
loop disconnect signal.

 

 

Up to 1024 zones are possible using a      
VIP-801 unit per zone for audio output.

 

 

Dimensions 

V-1094A: 

4.44"H x 2.75"W x 2.88"D 

 

(11.28cm x 6.99cm x 7.32cm) 

V-9937: 

8.20”H x 4.55”W x 2.30”D 

 

(20.85cm x 11.56cm x 5.84cm) 

V-2000A: 

7.75"H x 5.8"W x 2.6"D 

 

(19.69cm x 14.73cm x 6.6cm) 

V-2001A: 

7.09"H x 9.0"W x 2.4"D 

 

(18.0cm x 22.86cm x 6.1cm) 

V-2003A: 

7.13"H x 10.00"W x 3.00"D 

 

(18.1cm x 25.4cm x 7.62cm) 

V-2006A: 

10.9"H x 13.00"W x 2.69"D 

 

(27.7cm x 33.0cm x 6.83cm) 

V-2924A: 

17.5"H x 10.3"W x 3.06"D 

 

(44.45cm x 26.26cm x 7.77cm) 

V-2925A: 

17.5"H x 8.37"W x 3.06"D 

 

(44.45cm x 21.26cm x 7.77cm) 

V-2926: 

5.3"H x 3.0"W x 1.1"D 

 

(13.46cm x 7.620cm x 2.79cm)  

V-2928: 

5.3"H x 3.0"W x 1.1"D 

 

(13.46cm x 7.620cm x 2.79cm) 

V-1109RTVA: 

7.13"H x 5.9"W x 2.13"D 

 

(18.11cm x 14.99cm x 5.41cm) 

VIP-801: 

1.38”H x 6.20”Wx 5.31”D 

 

(3.50cm x 15.75cm x 13.49cm) 

VIP-811: 

1.38”H x 6.20”Wx 5.31”D 

 

(3.50cm x 15.75cm x 13.49cm) 

VIP-821: 

1.38”H x6.20”Wx 5.31”D 

 

(3.50cm x 15.75cm x 13.49cm) 

 
 
 
 

Environment 

Control Units: 
 

Temperature 

0 to +40 degrees C 

 Humidity 

0-85% 

non-precipitating 

 
Inside Speakers: 
 

Temperature 

-20 to +55 degrees C 

 

Humidity 

0-95% non-Precipitating  

 
Horn Speakers: 
 

Temperature 

-20 to +55 degrees C 

 Humidity 

0-95% 

non-precipitating 

 

Control Unit Power Requirements 

*VPU = Valcom Power Unit 

 

VIP Power:  VIP units are IEEE 802.3af 
compatible, class 3 devices.  If Power over 
Ethernet (PoE) is not available, the VIP-801 / 811 
/ 821 can be powered by a VIP-324D power 
supply. 

Table 1 

Control Unit 

"A"  Battery 

"B" Battery 

  VPU * 

V-1094A - 50 

mA 

-1 

V-2000A 

Supplies 600 milliamps, 

filtered 

+12 

V-2001A 

Supplies 1 Amp, filtered 

+20 

V-2003A 

Supplies 1.Amp, filtered 

+20 

V-2006A 

Supplies 1.5 Amp, filtered 

+30 

V-2924A/V-

2925A 

A. C. Line Powered 

V-1109RTVA 

60 mA 

250 mA 

-6 

 

V-9937 

- 200mA 

-4 

VIP- 

801/811/821 

See VIP power note below 

Содержание ONE-WAY PAGING SYSTEM

Страница 1: ...required Page port some with N O CC Station level access available with appropriate adapter Stand alone with dedicated single line sets 1A2 line button line card required on most units Capacity All un...

Страница 2: ...9 D 27 7cm x 33 0cm x 6 83cm V 2924A 17 5 H x 10 3 W x 3 06 D 44 45cm x 26 26cm x 7 77cm V 2925A 17 5 H x 8 37 W x 3 06 D 44 45cm x 21 26cm x 7 77cm V 2926 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2...

Страница 3: ...any of the following 1 zone V 2000A 1 zone V 2001A 3 zones w all call V 2003A 6 zones w all call V 2006A 9 zones w all call V 1109RTVA 24 zones w all call V 2924A 24 zone expansion module up to 96 tot...

Страница 4: ...one page units may not be used on page port output The V 2003A and V 2006A may be used on certain page ports that have an associated page port contact closure and support DTMF signaling Station level...

Страница 5: ...f Connections to a Valcom Page Control Interface Your Telephone or Telephone System SYSTEM INSTALLATION General These instructions will provide a basic understanding for wiring Valcom one way paging e...

Страница 6: ...g areas or light manufacturing Noisy 80 90dB This includes machine shops or heavy manufacturing Very Noisy Greater than 90dB This would include areas where talking to another person is very difficult...

Страница 7: ...peaker amplifier and volume control in a suitable baffle or housing The speakers and control units require a 24VDC power supply 48VDC for the V 1038 to operate Connections from the control unit to the...

Страница 8: ...the microphone offensive feedback cannot occur The Stacking Feedback Eliminator V 9964 can control up to 150 amplified speakers or horns in a single zone The Stacking Feedback Eliminator V 9964 can be...

Страница 9: ...elephone cable versus installing both telephone cable and 70 volt shielded paging cable Unlimited one way speaker expansion since each speaker is self amplified Jobs requiring explosion proof systems...

Страница 10: ...9915 5 Backbox are made of Borg Warner Flamex fire retardant 94 0 material and may only be ordered in multiples of five 5 The V 9904M 5 V 9914M 5 and V 9915M 5 metal bridges and backboxes may only be...

Страница 11: ...20 20 30 6 0 Background Music X X X X X X All Call X X X X Night Ringing Tones X X X Note 1 X Time Clock Tones X X X Add V 9927A X Power Supply Built In X X X X X Group Call X X Battery Back up Input...

Отзывы: