background image

 

 

6 947100 

Track Style Speakers

The 1 watt version will cover an area up to 600 
sq. feet.  These speakers should be spaced 
approximately 20 feet apart.  Good quality page 
audio will be heard up to 30 feet in front of the 
speaker. 
   
The 5 watt version will cover up to 3,600 sq. feet.  
Depending upon the height of the installed 
speaker, good quality paging will be heard up to 
60 ft. in front of the speaker. 

 

Pendant Speaker

The area covered by a pendant speaker is 
determined by the mounting height.  Refer to 
Table 3 & 4 for speaker coverage. 
 

Table 3 - Ceiling Height Spacing/Coverage 

Ceiling  
Height (ft.) 

< 8 

10 12 15 25 

Spacing 

(ft.) 

16 20 25 30 35 

Approximate 
Coverage (ft

250 350 500 800

100

Wall Speakers:  One per 600 sq. ft. spaced 20 ft. apart 
Corridor Speakers (bi-directional):  Spaced 35 ft. apart 

 

Table 4 - Horn Spacing/Coverage

 

Location 

5 Watt 

15 Watt 

30 Watt 

Quiet 

50-65dB 

110' 

(12,000 

ft

N/A N/A 

Moderate 

65-80dB 

80' 

(6,400ft

N/A N/A 

Noisy 

80-90dB 

50' 

(2,500ft

75' 

(5,600ft

N/A 

Very  

Noisy 

90+dB 

30' 

(900ft

45' 

(2,000ft

60' 

(3,600ft

*Contact Valcom Technical Support 

 

Noise Level Definitions: 
Quiet:

 

50-65dB.  

This would include areas such 

as waiting rooms or doctors' examination rooms. 
 

Moderate:  65-80dB.

  This includes areas such 

as warehouses, shipping areas, or light 
manufacturing. 
 

Noisy:  80-90dB.

  This includes machine shops 

or heavy manufacturing.

Very Noisy:  Greater than 90dB.

  This would 

include areas where talking to another person is 
very difficult.  Workers may be required to wear 
earplugs. 

 
NOTE 1: 

In areas where the sound level 
exceeds 100dB, consideration should 
be given to using a code call unit 
(V-9923B) for tone signaling instead 
of using voice paging.  In extreme 
ambient noise, it is generally easier to 
identify a tone code than to discern 
speech. 

NOTE 2:

 

Reverberant Areas - To increase the 
intelligibility of paging in reverberant 
areas, horns should be mounted 
closer to the people being paged, in 
effect, mounted at a lower height, 
closer together and angled towards 
the floor. 

 

Speaker Cabling 

All Valcom one-way amplified speakers 
require 2 pairs to operate.  Standard CAT 
3/5/5E/6 telecom/ data cable may be used.  
Existing telephone wire and feed cables may 
also be used.  Refer to Tables 5 and 6 when 
planning a job. 
 
Audio pair:  The number of speakers looped 
on the audio pair is not critical unless you 
have a very large job.  Table 5 gives guidelines 
for the number of speakers per audio run. 
 
Power Pair:  The cable runs specified in Table 
6 are very important and MUST be followed for 
proper operation of the one-way paging 
speakers. 

 

Table 5 - Number of Speakers/Horns per Audio 

Run

 

Wire Run (Ft.) 

22 AWG 

24 AWG 

100 
200 
400 
800 

1600 

150 
150 
100 

50 
25 

120 
120 

60 
30 
15 

 
 
 
 
 
 
 
 

Содержание ONE-WAY PAGING SYSTEM

Страница 1: ...required Page port some with N O CC Station level access available with appropriate adapter Stand alone with dedicated single line sets 1A2 line button line card required on most units Capacity All un...

Страница 2: ...9 D 27 7cm x 33 0cm x 6 83cm V 2924A 17 5 H x 10 3 W x 3 06 D 44 45cm x 26 26cm x 7 77cm V 2925A 17 5 H x 8 37 W x 3 06 D 44 45cm x 21 26cm x 7 77cm V 2926 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2...

Страница 3: ...any of the following 1 zone V 2000A 1 zone V 2001A 3 zones w all call V 2003A 6 zones w all call V 2006A 9 zones w all call V 1109RTVA 24 zones w all call V 2924A 24 zone expansion module up to 96 tot...

Страница 4: ...one page units may not be used on page port output The V 2003A and V 2006A may be used on certain page ports that have an associated page port contact closure and support DTMF signaling Station level...

Страница 5: ...f Connections to a Valcom Page Control Interface Your Telephone or Telephone System SYSTEM INSTALLATION General These instructions will provide a basic understanding for wiring Valcom one way paging e...

Страница 6: ...g areas or light manufacturing Noisy 80 90dB This includes machine shops or heavy manufacturing Very Noisy Greater than 90dB This would include areas where talking to another person is very difficult...

Страница 7: ...peaker amplifier and volume control in a suitable baffle or housing The speakers and control units require a 24VDC power supply 48VDC for the V 1038 to operate Connections from the control unit to the...

Страница 8: ...the microphone offensive feedback cannot occur The Stacking Feedback Eliminator V 9964 can control up to 150 amplified speakers or horns in a single zone The Stacking Feedback Eliminator V 9964 can be...

Страница 9: ...elephone cable versus installing both telephone cable and 70 volt shielded paging cable Unlimited one way speaker expansion since each speaker is self amplified Jobs requiring explosion proof systems...

Страница 10: ...9915 5 Backbox are made of Borg Warner Flamex fire retardant 94 0 material and may only be ordered in multiples of five 5 The V 9904M 5 V 9914M 5 and V 9915M 5 metal bridges and backboxes may only be...

Страница 11: ...20 20 30 6 0 Background Music X X X X X X All Call X X X X Night Ringing Tones X X X Note 1 X Time Clock Tones X X X Add V 9927A X Power Supply Built In X X X X X Group Call X X Battery Back up Input...

Отзывы: