With the V-9940 and V-9970, this line condition 
may be quiet line sensing, a strict "time out" 
(disconnects after a selected period of time) or 
open loop disconnect of at least 150 milliseconds.  
Open loop is a service provided by the central 
telephone office and involves actually 
disconnecting the telephone line from the C. O. 
for a brief instant.  In some cases the "quiet line" 
may also be programmed via the PABX.  "Quiet 
line" implies that the PABX will not return any 
tones (dial tone, busy tone, and reorder tone . . . 
etc.) to the called station at the completion of the 
station to station call.  The telephone system may 
be tested for a "no returned tones" status with 
your test set; have someone call you on a station 
and then ask them to hang up . . . if you do not 
hear any tones, or if there is a delay of at least 10 
seconds before you hear any tones, then the 
"quiet line" (i.e. audio sense time-out) may be 
used.   
 
Ground start telephone lines are a good choice for 
use with the V-9940 since a ground start line will 
not return dial tone until a ground is applied to the 
ring lead. 
 
Additionally, the V-9970 recognizes re-order tones 
and dial tone as disconnect signals. 

 

The V-9940 can be used alone, or can provide 
access to Valcom multi-zone and talkback page 
control units.   
 
The V-9970 may be used to access the V-2003A 
and V-2006A multi-zone control units only.  The  
V-9970 is not compatible with any talkback page 
control units. 

 
 

Station Level
Page Adapter

  Page
Control /
Interface

 Incoming C. O.

or Centrex line or

a PABX Station

or

DIAGRAM 3

Block Diagram of Connections to a Valcom

Page Control/Interface

Your Telephone or
Telephone System

SYSTEM INSTALLATION 

General 

These instructions will provide a basic 
understanding for wiring Valcom one-way paging 
equipment and connecting it to a telephone 
system. 
 
For specific wiring information, consult the 
installation practice enclosed with the actual 
equipment being used

 

Precautions 

Do not locate Valcom equipment or cabling within 
18" of a power supply, electrical panel, or any 
equipment that generates electrical noise. 

 

Mounting 

The control equipment should be installed at the 
main distribution frame with the telephone system 
common equipment. 
 
The V-1109RTVA, may be mounted to the 
backboard, in a 7" KTU rack or mounting frames.  
A 66-type block and 25-pair pigtail with female 
amphenol connector, are required for connections 
to these units if the mounting frames are not used.  
Other control units are wall mount units with 
connections via either screw terminals, integrated 
punch down block, or a user supplied 66-type 
block. 

 

Speaker Spacing 

Ceiling Speakers

The area covered by a ceiling speaker depends 
on the height of the ceiling.  Refer to Table 3 for 
speaker coverage. 

 

Wall Speakers

:  

A wall speaker will cover up to 600 square feet.  
Wall speakers should be spaced 20 feet apart.  
Good quality paging will be heard up to 30 ft. in 
front of the speaker. 

 

Corridor Speakers

:

 

 

Corridor speakers should be mounted 8 to 12 feet 
high and spaced 30 to 40 feet apart. 

 

Horn Speakers

:

   

Refer to Table 4 for horn speaker coverage.  The 
first figure given is the side to side distance 
between the speakers.  It is also the distance in 
front of the speaker that you can expect to hear a 
good quality page.  The second figure given is the 
area being covered in square feet.

Содержание ONE-WAY PAGING SYSTEM

Страница 1: ...required Page port some with N O CC Station level access available with appropriate adapter Stand alone with dedicated single line sets 1A2 line button line card required on most units Capacity All un...

Страница 2: ...9 D 27 7cm x 33 0cm x 6 83cm V 2924A 17 5 H x 10 3 W x 3 06 D 44 45cm x 26 26cm x 7 77cm V 2925A 17 5 H x 8 37 W x 3 06 D 44 45cm x 21 26cm x 7 77cm V 2926 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2...

Страница 3: ...any of the following 1 zone V 2000A 1 zone V 2001A 3 zones w all call V 2003A 6 zones w all call V 2006A 9 zones w all call V 1109RTVA 24 zones w all call V 2924A 24 zone expansion module up to 96 tot...

Страница 4: ...one page units may not be used on page port output The V 2003A and V 2006A may be used on certain page ports that have an associated page port contact closure and support DTMF signaling Station level...

Страница 5: ...f Connections to a Valcom Page Control Interface Your Telephone or Telephone System SYSTEM INSTALLATION General These instructions will provide a basic understanding for wiring Valcom one way paging e...

Страница 6: ...g areas or light manufacturing Noisy 80 90dB This includes machine shops or heavy manufacturing Very Noisy Greater than 90dB This would include areas where talking to another person is very difficult...

Страница 7: ...peaker amplifier and volume control in a suitable baffle or housing The speakers and control units require a 24VDC power supply 48VDC for the V 1038 to operate Connections from the control unit to the...

Страница 8: ...the microphone offensive feedback cannot occur The Stacking Feedback Eliminator V 9964 can control up to 150 amplified speakers or horns in a single zone The Stacking Feedback Eliminator V 9964 can be...

Страница 9: ...elephone cable versus installing both telephone cable and 70 volt shielded paging cable Unlimited one way speaker expansion since each speaker is self amplified Jobs requiring explosion proof systems...

Страница 10: ...9915 5 Backbox are made of Borg Warner Flamex fire retardant 94 0 material and may only be ordered in multiples of five 5 The V 9904M 5 V 9914M 5 and V 9915M 5 metal bridges and backboxes may only be...

Страница 11: ...20 20 30 6 0 Background Music X X X X X X All Call X X X X Night Ringing Tones X X X Note 1 X Time Clock Tones X X X Add V 9927A X Power Supply Built In X X X X X Group Call X X Battery Back up Input...

Отзывы: