background image

 

                                                              3                                                               947593 

 

double gang or octagon outlet box.  If not 
attaching to an outlet box, use the enclosure as a 
template.  Hold the enclosure in the desired 
position on the wall and mark the location of 
mounting holes.  Depending on wall construction 
type, prepare the mounting hole locations on the 
wall to securely attach the enclosure. 
 
Wiring may be inserted through the large hole in 
the back of the enclosure, or through the 
knockout hole in the top of the enclosure.  Insert 
wiring for signal connections and relay 
connections (if used) through desired hole.  Use 
mounting hardware (not included) appropriate for 
the wall type to securely mount the enclosure to 
the wall. 
 
After making signal connections, align the 
grille/speaker assembly with the enclosure.  
Install the four supplied tamper-resistant screws 
through the 

grille into the enclosure.  Use a 1/8” 

security hex bit to tighten the screws securely. 
 

Power Connections 

The only method of powering a                       
VIP-9890AL-CB-IC Network Interface is via a 
Power over Ethernet (PoE) switch or power 
injector meeting the 802.3af specification.  

 

Make all required signal connections before 
connecting to Ethernet switch or power injector 
meeting the 802.3af specification. 
 

Network Connection 

The VIP-9890AL-CB-IC Network Interface has 
one RJ-45 NETWORK connector and one RJ-45 
Signal Output connector. 

 

Use a standard Ethernet patch cable to connect 
the NETWORK connector of the                      
VIP-9890AL-CB-IC Network Interface to an 
Ethernet switch.  
 

Signal Connections 

Use standard Category 5 UTP cable to connect 
the VIP-9890AL-CB-IC Network Interface to the 
Intercom unit.  Connect the RJ-45 jack (labeled 
Signal Output) on the Network Interface to the 
RJ-45 jack on the back of the speaker assembly 
using a standard Ethernet patch cable.  See 
Quick Start Installation, Figure A. 
 
For longer distances between the network 
interface and the speaker (up to 350’), VM-186 
adapters (not included), or other Standard 
Category 5 straight-through terminators, may be 
used to extend the signal line.  Refer to Quick 
Start Installation, Figure B. 

 

Door Relay Connections 

Access to the form C relay is provided via a three 
pin screw terminal block on the                       
VIP-9890AL-CB-IC speaker.  The common 
contact is the middle terminal.  The Normally 
Open contact is on the side labeled NO, the 
Normally Closed contact is  labeled NC. 
 
For higher security, the included VIP172L-RLY 
connection block can be used.  Please refer to 
the High Security Relay Quick Start Installation 
guide for installation details. 
 

Status Indicator Lights 

The VIP-9890A-CB-IC Network Interface has 2 
status indication lights on the Ethernet connector:

 

 
Green LED:

 (Link) Indicates Ethernet 

connection when illuminated. 
 

Yellow LED:

 (Activity) Indicator flashes to 

indicate network activity. 

 
Setup 

The VIP-9890AL-CB-IC will automatically acquire 
an IP address (using DHCP) and connect to the 
InformaCast server when connected to the 
network and powered up.  Information specific 
to your application will need to be programmed 
into the InformaCast server.  Refer to the 
InformaCast documentation for further 
Information. 

 

Содержание InformaCast VIP-9890AL-CB-IC

Страница 1: ...4 30 cm x 8 76 cm with brackets 8 22 W 20 87 cm Weight 2 10 lbs 0 95 kg Nominal Specifications Output Impedance 45 Ohms Output Level 100 dB 4 on axis Relay Current 1 AMP 24VDC Nominal Power Requirements Via 802 3af PoE Ethernet Switch Class 3 Environment Network Interface Temperature 0 to 40 C Humidity 0 to 85 non precipitating Intercom Unit Suitable for indoor or outdoor installation These produc...

Страница 2: ...ructions 3 Heed all warnings Respectez tous les avertissements 4 Follow all instructions Suivez toutes les instructions 5 Do not use this apparatus near water Ne pas utiliser cet appareil près de l eau 6 Clean only with dry cloth Nettoyer avec un chiffon sec 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions Ne pas bloquer les ouvertures de ventilati...

Страница 3: ...rk Interface to an Ethernet switch Signal Connections Use standard Category 5 UTP cable to connect the VIP 9890AL CB IC Network Interface to the Intercom unit Connect the RJ 45 jack labeled Signal Output on the Network Interface to the RJ 45 jack on the back of the speaker assembly using a standard Ethernet patch cable See Quick Start Installation Figure A For longer distances between the network ...

Страница 4: ...BROWN AUDIO WHITE BLUE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN WHITE BLUE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN VM 186 RJ45 BROWN BLUE VM 186 RJ45 BROWN BLUE WHITE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN WHITE BLUE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN BLUE SIGNAL OUTPUT NETWORK NETWORK INTERFACE Step 2 by pres...

Страница 5: ... device The relay can be activated by pressing the key on the answering telephone Step 2 Connect the IP Speaker to the VIP172 RLY with standard CAT5 T568A or T568B straight through cabling Step 3 Connect the punchdown block on the IP Speaker to the SIGNAL OUTPUT on the Network Interface with standard CAT5 cabling RJ 45 connector at Network Interface should be wired using T568B standard Solutions S...

Отзывы: