background image

 

                                                              4                                                               947593 

 

Step 3. Connect the RJ45 cable from the network.  This device is powered via

Power over Ethernet (PoE).  If PoE is unavailable from the network

Step 4. Program the IP Speaker using the VIP-102B IP Solutions Setup Tool.

Step 3

S

IG

N

A

O

U

TP

U

T

N

E

TW

O

R

K

NETWORK

INTERFACE

IP SPEAKER

Step 1. An optional relay output is provided for activating electric door controls,

strike plates, gates, etc.  A Normally Open (NO) and Normally Closed (NC)
connection is available. Consult the door equipment manufacturer’s

documentation for connections to their device.  The relay can be activated

Step 2. Connect the IP Speaker to the Network Interface.  If the IP Speaker is close

to the Network Interface, a standard Patch Cable may be used to connect
between them (Figure A).  For longer distances, the VM-186 RJ45 Junction
Boxes can be used to extend up to 350' between the IP Speaker and Network

switch then an inline power injector will be required.

Step 1

Step 2

350' MAXIMUM DISTANCE

CAT 3/5/6 UTP

Quick Start Installation

Step 3

VM-186 COLOR CODES  -  FUNCTION

ORANGE & WHITE/ORANGE  -  LED

GREEN & WHITE/GREEN  - RELAY CONTROL

BLUE & WHITE/BLUE  -  CALL SWITCH

BROWN & WHITE/BROWN  -  AUDIO

WHITE/BLUE

BLUE

WHITE/ORANGE

ORANGE

WHITE/GREEN

GREEN

WHITE/BROWN

BROWN

WHITE/BLUE

BLUE

WHITE/ORANGE

ORANGE

WHITE/GREEN

GREEN

WHITE/BROWN

BROWN

VM-186

RJ45

BROWN

BLUE

VM-186

RJ45

BROWN

BLUE

WHITE/BLUE

WHITE/ORANGE

ORANGE

WHITE/GREEN

GREEN

WHITE/BROWN

BROWN

WHITE/BLUE

BLUE

WHITE/ORANGE

ORANGE

WHITE/GREEN

GREEN

WHITE/BROWN

BROWN

BLUE

S

IG

N

A

O

U

TP

U

T

N

E

TW

O

R

K

NETWORK

INTERFACE

Step 2

by pressing the # key on the answering telephone.

Interface (Figure B).

FIGURE A

FIGURE B

350' MAXIMUM DISTANCE

R

 0

03

N/O

N/C

COM

RJ45

IP SPEAKER

Step 1

R

 0

03

N/O

N/C

COM

RJ45

 

TECHNICAL ASSISTANCE 

Assistance in troubleshooting is available from 
the factory. Call (540) 563-2000 and press 1 for 
Technical Support or via email at 
[email protected]. 

When requesting assistance, you should include 
all available information.  Information and trouble-
shooting procedures are available on the Valcom 
website at www.valcom.com. 

Valcom equipment is not field repairable.  
Valcom, Inc. maintains service facilities in 
Roanoke, VA.  Should repairs be necessary, 

attach a tag to the unit clearly stating your 
company name, address, phone number, contact 
person and the nature of the problem. Send the 
unit to:

 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056  

 

WARRANTY 

Warranty information may be found on our 
website at www.valcom.com/warranty. 

 

 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание InformaCast VIP-9890AL-CB-IC

Страница 1: ...4 30 cm x 8 76 cm with brackets 8 22 W 20 87 cm Weight 2 10 lbs 0 95 kg Nominal Specifications Output Impedance 45 Ohms Output Level 100 dB 4 on axis Relay Current 1 AMP 24VDC Nominal Power Requirements Via 802 3af PoE Ethernet Switch Class 3 Environment Network Interface Temperature 0 to 40 C Humidity 0 to 85 non precipitating Intercom Unit Suitable for indoor or outdoor installation These produc...

Страница 2: ...ructions 3 Heed all warnings Respectez tous les avertissements 4 Follow all instructions Suivez toutes les instructions 5 Do not use this apparatus near water Ne pas utiliser cet appareil près de l eau 6 Clean only with dry cloth Nettoyer avec un chiffon sec 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions Ne pas bloquer les ouvertures de ventilati...

Страница 3: ...rk Interface to an Ethernet switch Signal Connections Use standard Category 5 UTP cable to connect the VIP 9890AL CB IC Network Interface to the Intercom unit Connect the RJ 45 jack labeled Signal Output on the Network Interface to the RJ 45 jack on the back of the speaker assembly using a standard Ethernet patch cable See Quick Start Installation Figure A For longer distances between the network ...

Страница 4: ...BROWN AUDIO WHITE BLUE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN WHITE BLUE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN VM 186 RJ45 BROWN BLUE VM 186 RJ45 BROWN BLUE WHITE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN WHITE BLUE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN BLUE SIGNAL OUTPUT NETWORK NETWORK INTERFACE Step 2 by pres...

Страница 5: ... device The relay can be activated by pressing the key on the answering telephone Step 2 Connect the IP Speaker to the VIP172 RLY with standard CAT5 T568A or T568B straight through cabling Step 3 Connect the punchdown block on the IP Speaker to the SIGNAL OUTPUT on the Network Interface with standard CAT5 cabling RJ 45 connector at Network Interface should be wired using T568B standard Solutions S...

Отзывы: