MC122 - MCP-4J Control Unit
Section 5 - Operation
73
Stitch Mode
Stitch Mode is very similar to Pattern Mode, with the exception that the glue “patterns” are applied in a stitch-like
pattern.
Setting the patterns for Stitch Mode is very similar to setting the patterns for Pattern Mode.
The difference between Pattern Mode and Stitch Mode is the application of the glue. The Pattern Mode applies a
continuous strip of glue for the pattern length specified. The Stitch Mode applies the glue in a stitch pattern for the
pattern length specified. To illustrate:
“Stitch Not Possible” Warning:
If a valve channel has a long pattern, configured with a small stitch length and stitch
gap, it is possible to reach maximum table storage (maximum is 500 positions). If the pattern entered exceeds the
maximum, it may be cut short when gluing is attempted.
When a pattern is entered, the control calculates each time the valve is turned off or on (each transition between
stitches), storing the distances as encoder pulses between each of those transitions. The table has 500 positions
maximum.
Example:
If a pattern of 100” were entered with stitch gap of 0.1”, there would be 1000 transitions. As a result, the
system would lay a 50” pattern and then shut off.
The
“Stitch Not Possible” Warning
symbol will appear if the pattern entered is
not
possible.
Содержание MCP-4J
Страница 4: ......
Страница 10: ...Table of Contents MC122 MCP 4J Control Unit 6 ...
Страница 12: ...Section 1 Introduction MC122 MCP 4J Control Unit 2 ...
Страница 20: ...Section 2 Safety and Use MC122 MCP 4J Control Unit 10 ...
Страница 38: ...Section 3 Basic features MC122 MCP 4J Control Unit 28 Wiring the Scanner Cable Continued ...
Страница 59: ...MC122 MCP 4J Control Unit Section 4 Programming 49 Protected Level Mode Continued ...
Страница 100: ...Section 6 Maintenance MC122 MCP 4J Control Unit 90 ...
Страница 102: ...Section 7 Specifications MC122 MCP 4J Control Unit 92 ...
Страница 104: ...Section 8 Part Number List MC122 MCP 4J Control Unit 94 MCP 4J Vertical with EPC 074xx084 JWT6119 dwg ...
Страница 107: ...MC122 MCP 4J Control Unit Section 8 Part Number List 97 MCP 4J Vertical w o EPC 074xx085 KMP0153 dwg ...
Страница 110: ...Section 8 Part Number List MC122 MCP 4J Control Unit 100 MCP 4J Vertical 3NC Tipsealer 074xx086 JWT6546 dwg ...
Страница 113: ...MC122 MCP 4J Control Unit Section 8 Part Number List 103 MCP 4J Horizontal with EPC 074xx087 JWT6113 dwg ...
Страница 116: ...Section 8 Part Number List MC122 MCP 4J Control Unit 106 MCP 4J Horizontal w o EPC 074xx088 KMP0154 dwg ...
Страница 122: ...Section 8 Part Number List MC122 MCP 4J Control Unit 112 MCP 4J Horizontal Dual External EPC 074xx090 KMP0159 dwg ...
Страница 130: ...Section 8 Part Number List MC122 MCP 4J Control Unit 120 ...
Страница 132: ...Section 9 Warranty MC122 MCP 4J Control Unit 122 ...
Страница 134: ...Section 10 Service MC122 MCP 4J Control Unit 124 ...
Страница 136: ...Appendix A Job Charts MC122 MCP 4J Control Unit 126 Job Number Job Name Description ...
Страница 146: ...Appendix C Instruction Sheets for the MCP 4J MC122 MCP 4J Control Unit 136 ...
Страница 156: ...MCP 4J Quick Start Guide IS0368 Valco Melton 10 Operator Panel ...