Sequential Start
– Gun
The Sequential Start function allows the gun to begin heating after the
tank reaches a specified temperature offset below the setpoint
temperature. This feature is used to reduce adhesive degradation
caused from heating adhesive in the gun for long periods while waiting
for the tank to reach temperature.
The sequential start range is 0°F to 450°F (0°C to 250°C). The default
factory setting is OFF.
This parameter can be accessed in Password Level 2 or higher.