3.5. PNEUMATIC INSTALLATION
Connect the air line to the regulator. Make sure the air-connection line
has the capacity necessary for proper pump operation.
3.6. ELECTRICAL INSTALLATION
3.6.1 Routing Low-Voltage Leads
Warning: Failure to observe could result in personal injury, death, or
damage to equipment.
When routing low-voltage leads, follow these guidelines:
Do not route low-voltage leads in the same conduit as wires
carrying a high-current load.
Do not route low-voltage leads adjacent to, or across wires
carrying a high-current load. If low-voltage leads must cross or
run parallel to wires carrying high current, keep the leads at
least 6" (152 mm) from high-current wires.
Do not splice or solder leads.
Trim leads to the required length. Leads should be only as long
as necessary for installation.
All wiring should be in conduits or wireways.
Air inlet
Service
wires