MUS0330202
03/10/2014
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 [email protected] www.valcomelton.com
115
8.6. REPAIRING ELECTRIC COMPONENTS:
If
one of the electric components needs to be repaired, proceed
according to the part listings in Addendum A and the electric diagrams
in Addendum B.
All these operations should be performed with the machine switched
off at the mains and disconnected from the main air circuit, making
sure that the system has been properly bled and depressurised.
WARNING:
When a fuse is blown, it is essential to replace it with fuses
supplied with the equipment.
If fuses are not available, use ULTRAFAST fuses with the same
characteristics.
ELECTRONIC CARD WARNING
During equipment manipulation, avoid contact with electronic elements
and connector metallic parts; elements susceptible to electrostatic
discharge.
8.7. REPAIRING VACUUM FEEDER
For any electrical part requiring replacement, contact your Melton
dealer. For mechanical, stress the following:
Changing the vibrator module
Locate the vibrator module, Remove the air hose fitting.
mounted on the loader arm
Press the plunger
Remove the two screws and Install the new module with
remove the module
the screws