The customer connection interface is a 10-pin terminal connector located at
the front of the 5 zone board, on the right side. The numbered plug starts
with “1” at the left end (looking at the wire entrance side of the plug).
There are two opto isolated user selectable inputs rated for +24V@15mA
and one dry contact user selectable output rated for 250V@5A.
Inputs and outputs can be programmed for the following functions (see
Section – Setup. “Peripherals” for programming instructions):
Input 1
Input 2
Output 2
Disabled
Disabled
Disabled
Setback
Setback
System Ready
Auto Setback
Auto Setback
Ready & Pump On
Heater On/Off
Heater On/Off
Alarm
Pump On/Off
Pump On/Off
A +24V DC output is provided for input control and small load outputs only.
This output is rates for +24V DC@250 mA Max. The unit can be connected