VAL VLC-1230-4 Скачать руководство пользователя страница 6

Rev. 1.2 

 

7.Control with External Signals 

CAUTION

 

Use output signal cable of 3m or shorter. 
Do not apply too high current and voltage. 
Do not use external connector except SELV circuit with reinforced insulation or 
a circuit with double insulation.

 

 
 
Connector Communications Specifications 

No. 

Signal 

Tx 

Rx 

NC 

GND 

 
Command Formats 
       

                                                                                                                       

 

Channel Specification

Channel

CH1

CH2

CH3

CH4

Set Value

00

01

02

03

Lighting Mode Setting

40μS

80μS

120μS 200μS 600μS 1.2mS

4mS

10mS

20mS

40mS

Channel

F01

F02

F03

F04

F05

F06

F07

F08

F09

F10

Set Value

01

02

03

04

05

06

07

08

09

10

Status

Strobe Mode

Receive Data

Light Intensity Setting

Lighting Mode Setting

ON/OFF Setting

Function

Header Channel specification

@

00 to 03

(Refer toChannel 

Specification)

FF: All channels

(ON/OFF setting only)

O

N

NG

01: Command Error 
02: Checksum Error
03: Setvalue out of Range Error

Receive Command

OK

-----

ID 

specification

00 (Fixed)

Checksum

00 to FF            

(Refer to 
Checksum)

<CR><LF>

Delimiter

Channel Specification

Channel

CH1

CH2

CH3

CH4

Set Value

00

01

02

03

Checksum

Header Channel

Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9

Character

@

0

1

F

1

2

5

0

0

ASCII (hexadecimal) 40 hex 30 hex 31 hex 46 hex 31 hex 32 hex 35 hex 30 hex 30 hex 1DF hex

*Set value that are higher than 10 are not valid.

The codes of the ASCII characters
from the header to the ID are 
added,
the lowest byte is converted to
hexadecimal, and two characters are
sent.

Example: Setting the Light Intensity of Channel 2 to 125

Sent command

ID

Total

Send Data (*1)

Instruction

Data (*2)

Light Intensity Setting

F

000 to 255 (000:Min. Intensity, 255:Max. Intensity)

000

Lighting Mode Setting

S

01 to 10 (Refer to Lighting Mode Settings)

00

ON/OFF Setting  (*3)

L

0 : Not Lit , 1 : Lit  (*4)

-----

(*5)

*1: Send a data within 4 seconds from 'Header' to 'Delimiter', otherwise time-out error occurs and command data will be rejected.
*2: Specify all numbers in Decimal format.
*3: ON/OFF settings from EIA-232-D communications without regards to trigger logic switch, turned OFF at '0' and ON at '1'. ON/OFF setting will not be held after turning
    the power off.
*4: When operating EIA-232-D Communications and trigger signal input at same time in ON/OFF mode.
    When Trigger H/L logic switach is at H : if either controls setting to OFF setting, Light unit will be turned OFF.
    When Trigger H/L logic switach is at L : if either controls setting to ON setting, Light unit will be turned ON.
*5: Defalt setting for trigger logic switch is H ='1(ON)' and L='0(OFF)'.

Sent command

@

Function

Header

Channel specification

00 to 03

(Refer toChannel 

Specification)

FF: All channels

(ON/OFF setting only)

Default

00 (Fixed)

ID 

specification

Checksum

Delimiter

00 to FF 

(Refer to 
Checksum)

<CR><LF>

Communications protocol 

EIA-232-D 

Baud rate 

38,400 bps 

Data bit length 

8 bits 

Parity bit 

None 

Stop bits 

1 bit 

 

 

Содержание VLC-1230-4

Страница 1: ... safety please read this manual thoroughly before starting operation Keep this manual for the whole product lifetime The following warning symbols are used in this manual Be sure to fully understand the contents WARNING A warning denotes a hazard that can cause severe injury or death CAUTION A caution denotes a hazard that can cause injury or damage of equipment ...

Страница 2: ...her lighting unit over current may cause a fire or heat CAUTION 1 USE the extension or remote cables 3m maximum to prevent power drop by voltage reduction or malfunction by noise 2 Installation of the product 1 Place horizontally in a well ventilated space on the rubber feet at the bottom of the unit 2 Do not topple or lay on its side 3 Do not put on unstable or vibrational place 4 Do not use in e...

Страница 3: ...ectors SMP 02V BC JST 1 output 2 output Insulation resistance 500MΩ min Withstand voltage AC1500V minute External control connectors Trigger input MIL connector MIL C 83503 compliant 10 pole For setting the light intensity and lighting mode e CON 3 pole Intensity Control INT Control manually by volume knobs EXT Remote control by external EIA 232 D Strobe Control NOR The lights are always ON STR St...

Страница 4: ...ings for Light Unit connected to output connector CH3 CH4 lit Lit when changing settings for Light Unit connected to output connector CH4 Control Switch Selects internal INT or external EXT control mode Mode Switch Selects normal NOR or strobe STR control mode Trigger H L Logic Switch Selects the logic of the trigger signal External Control Connector For external control with RS 232C communication...

Страница 5: ...S 232C or TRIG IN connector on front panel 4 On Off Control It is possible to turn off the light by inputting off signal by External control mode 5 Error Signal Error indicator on front panel will be on if an error of LED lighting unit detected such as breaking of wire Error signal from external signal connector will be output at the same time It does not identify error of CH1 or CH2 or CH3 or CH4...

Страница 6: ...s of the ASCII characters from the header to the ID are added the lowest byte is converted to hexadecimal and two characters are sent Example Setting the Light Intensity of Channel 2 to 125 Sent command ID Total Send Data 1 Instruction Data 2 Light Intensity Setting F 000 to 255 000 Min Intensity 255 Max Intensity 000 Lighting Mode Setting S 01 to 10 Refer to Lighting Mode Settings 00 ON OFF Setti...

Страница 7: ...01N0300B3CRLF Setting the Lighting Mode Specify the ID and channel and set the lighting mode Setting example Send data Receive data When ON Receive data When NG Setting the lighting mode to Strobe Mode at 200μs for CH2 of the VLC 1230 4 that the ID set to 00 00S0400B8CRLF 00O0050CRLF 00N0300B2CRLF To set ON OFF Signal in ON OFF mode Specify the ID and the channel and set ON OFF signal Setting exam...

Страница 8: ... turned ON Connector Layout External Trigger Input Connector Plug External Trigger Signal Connection Example Signal Specifications Rated input voltage Maximum input voltage ON voltage ON current OFF voltage OFF current ON OFF response time Input impedance 24 VDC 26 4 VDC 14 4 VDC min 3 mA max 5 VDC max 1 mA max 10 μs max 7 5kΩ per terminal TRIG IN 1 2 3 10 5 7 9 4 6 8 External Circuits VLP 2430 4 ...

Страница 9: ...r OFF according to the external trigger signal input Strobe Mode The Light Units are turned ON for the set time after the external trigger signal input Trigger Input Sequence Diagram A pulse width of ON signal shall be 10μs or more The Light Units will be turned on for at least 40μs even when the input ON signal is less than 40μs If another trigger is input before the Light Units turns OFF in Stro...

Страница 10: ...e performance specifications etc by customers after the day of product delivery Faults or damage that occur due to use of the product other than for its designed purpose Faults or damage that occur due to natural or human causes such as saltwater air damage gas damage earthquakes floods fire lighting or armed conflicts Disclaimer VS Technology Thailand Co Ltd shall not be responsible for any appen...

Отзывы: