TECHNICAL DATA
Outdoor unit
VAI 6-025 WNO VAI 6-035 WNO VAI 6-050 WNO VAI 6-065 WNO
Indoor Unit
VAI 6-025 WNI VAI 6-035 WNI VAI 6-050 WNI VAI 6-065 WNI
Heating
(A
verage climate)
TOL
Tol (temperature operating limit)
°C
-10
-10
-10
-10
Pdh (declared heating cap)
kW
2,50
2,6
3,5
4,4
COPd (declared COP)
2,50
2,3
2,6
2,3
TBivalent
Tbiv (bivalent temperature)
°C
-7
-7
-7
-7
Pdh (declared heating cap)
kW
2,48
2,83
4
4,9
COPd (declared COP)
2,60
2,5
2,8
2,5
A Condition
(�7°C)
Pdh (declared heating cap)
kW
2,48
2,83
4
4,9
COPd (declared COP)
2,60
2,5
2,8
2,5
B Condition
(2°C)
Pdh (declared heating cap)
kW
1,51
1,72
2,4
3,1
COPd (declared COP)
3,80
3,96
4
3,8
C Condition
(7°C)
Pdh (declared heating cap)
kW
0,97
1,11
1,6
1,9
COPd (declared COP)
4,80
5,2
4,7
4,7
D Condition
(12°C)
Pdh (declared heating cap)
kW
0,43
0,49
2
2
COPd (declared COP)
4,90
5,6
5,7
5,6
Pto (Thermostat off) (Cooling/Heating)
kW
0.042 / 0.013 0.0395 / 0.0127 0.045 / 0.013
0.0775 / 0.013
Cooling
Psb (Standby mode cooling)
kW
0,001
0,001
0,001
0,001
Pcycc
kW
N.A.*
N.A.*
N.A.*
N.A.*
EERcyc (cycling interval efficiency for cooling)
N.A.*
N.A.*
N.A.*
N.A.*
Cdc (Degradation cooling)
0,25
0,25
0,25
0,25
Pck (Crankcase heater mode)
kW
N.A.*
N.A.*
N.A.*
N.A.*
Poff (Off mode)
kW
N.A.*
N.A.*
N.A.*
N.A.*
Heating
Psb (Standby mode heating)
kW
0,001
0,001
0,001
0,001
Pcych
kW
N.A.*
N.A.*
N.A.*
N.A.*
COPcyc
N.A.*
N.A.*
N.A.*
N.A.*
Cdh (Degradation heating)
0,25
0,25
0,25
0,25
* We have different sound level datas according to different air flow
volume or frequencies, not according to the working temp.
i
NOTE!
As part of its policy for ongoing improvements of
its products, Vaillant reserves the right to modify