TECHNICAL DATA
14
Additional datasheet
Outdoor unit
VAI 6-025 WNO VAI 6-035 WNO VAI 6-050 WNO VAI 6-065 WNO
Indoor Unit
VAI 6-025 WNI VAI 6-035 WNI VAI 6-050 WNI VAI 6-065 WNI
Outdoor Sound Power Level Cooling
Nom.
dB(A)
63
63
63
68
Outdoor Sound Power Level Heating outdoor 7(6) /
indoor 20 (max 15)
dB(A)
N.A.*
N.A.*
N.A.*
N.A.*
Indoor
Sound Power Level Cooling
Nom.
dB(A)
54
54
58
63
Outdoor Rated Airflow
Cooling
m³/min
1800
1800
3200
4000
Heating
m³/min
1800
1800
3200
4000
Indoor
Rated Airflow
Cooling
m³/min
600
580
850
1000
Indoor
Rated Airflow
Heating
m³/min
600
580
850
1000
Refrigerant type
R410A
R410A
R410A
R410A
GWP
1975
1975
1975
1975
GWP
Fixed Text
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute
less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant
fluid with a GWP equal to
1975
. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact
on global warming would be
1975
times higher than 1kg of CO2 ,over a period of 100 years. Never try to interfere with the
refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
Capacity control
Variable
Variable
Variable
Variable
Cooling function included
Yes
Yes
Yes
Yes
Heating function included
Yes
Yes
Yes
Yes
Average climate included
Yes
Yes
Yes
Yes
Cold season included
No
No
No
No
Warm season included
No
No
No
No
Cooling
Energy label
Yes
Yes
Yes
Yes
Pdesign
kW
2,7
3,5
5,2
6,4
SEER
5,6
6,1
5,6
5,1
Annual energy consumption
kWh
168
201
325
439
Heating
(A
verage climate)
Energy label
Yes
Yes
Yes
Yes
Pdesign
kW
2,8
3,2
4,5
5,8
SCOP
3,8
4
3,8
3,8
Annual energy consumption
kWh
1032
1120
1658
2137
Required back up heating cap at design conditions kW
0,3
0,6
1
1,4
Cooling
A Condition (35°C � 27/19)
Pdc
kW
2,7
3,5
5,2
6,2
EERd
3,00
2,72
3,1
2,8
B Condition (30°C � 27/19)
Pdc
kW
1,99
2,58
3,9
4,5
EERd
4,20
4,5
4,6
4,3
C Condition (25°C � 27/19)
Pdc
kW
1,28
1,66
2,5
3
EERd
7,00
7,8
6,6
5,8
D Condition (20°C � 27/19)
Pdc
kW
0,57
0,74
2,2
2,1
EERd
9,40
10,5
9,1
7,1
EN