![Vaillant VAI 6-025 WN Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/vaillant/vai-6-025-wn/vai-6-025-wn_installation-manual_3275279022.webp)
20
VAI 6 WN-I_EN - 06/14 - Vaillant
TECHNICAL DATA
13
Technical specifications
Units
VAI 6-025 WN
VAI 6-035 WN
VAI 6-050 WN
VAI 6-065 WN
Power supply
V/Ph/Hz
230/1/50
Cooling Capacity
kW
2,70
3,50
5,28
6,45
Power input
kW
0,87
1,17
1,63
2,18
Operating current
A
3,80
5,20
7,20
9,70
SEER
5,60
6,10
5,60
5,10
Heating Capacity
kW
2,80
4,00
5,80
7,00
Power input
kW
0,90
1,20
1,76
2,22
Operating current
A
4,00
5,30
7,80
9,80
SCOP
3,80
4,00
3,80
3,80
Indoor Unit
Air Flow volume
m
3
/h
300 / 400 / 500 / 600 300 / 400 / 500 / 580 550 / 650 / 780 / 850 550 / 700 / 800 / 1000
Sound Pressure level
dB(A)
28 / 34 / 39 / 41
30 / 35 / 40 / 42
35 / 40 / 43 / 48
39 / 42 / 47 / 51
Outdoor Unit
Air Flow volume
m
3
/h
1800
1800
3200
4000
Sound pressure level
dB(A)
51
53
56
58
Refrigerant
R410A
Refrigerant charge
gr
700
850
1350
1800
Compressor type
Rotary
Expansion system
EEV
EEV
Capillary
Capillary
Pipe Connections
Diameter liquid/gas pipes
Inches
1/4'' - 3/8''
1/4'' - 3/8''
1/4'' - 1/2''
1/4'' - 5/8''
Max. piping length*
m
15*
15*
25*
25*
Max. height IU under OU
m
10
10
10
10
Max. height OU under IU
m
10
10
10
10
Minimum distance between OU and IU
m
3
3
3
3
Chargeless length
m
5,0
5,0
5,0
5,0
Additional charge per metre
gr
20
20
20
50
Table 13.1
Technical specifications
.
a
WARNING!
*
Maximum piping length
.
•
The curves made in the refrigerant lines count as
one extra meter per curve.
i
NOTE!
As part of its policy for ongoing improvements of
its products, Vaillant reserves the right to modify
these specifications without prior notice
.