System bypass
●
Refer to the important information
and initial preparation on page 45.
●
Release central heating water
pressure.
●
Remove spring clip (
2
)
●
Undo union (
1
), remove
bypass/connecting pipe.
●
Pull apart bypass and connecting
pipe.
●
Re-assemble in reverse order.
Diverter valve
●
Refer to the important information
and initial preparation on page 45.
●
Release central heating water
pressure.
●
Disconnect the plug (
4
) from the
diverter valve.
●
Remove the spring clip (
5
).
●
Undo the unions (
6
) and remove
the diverter valve.
●
Re-assemble in reverse order.