FAULT FINDING
Sheet B
Check operation of pump and fan
Tu
rn
off the main ON/OFF control to the
"0" position
Diconnect the power supply to the boiler
Go to sheet A
Check transfor
mer 230 V
AC primar
y
(black/red) and approx. 17 VDC secondar
y
(blue/brown)
Check/replace pump
Replace fuse F1
If fan commences operation, exchange
gas valve
After approx. 20 secs.
Does fuse F1 blow?
Produce central heating demand.
Does fuse blow immediately?
Tu
rn
the main ON/OFF control to the "1"
position
Does green power on indicator glow?
Ye
s
No
No
No
Ye
s
Check/replace fan
Replace electronic board
No
Ye
s
Ye
s
Does green power on indicator glow?