54
PARTS REPLACEMENT
2
2
1
Fig. E.15: Pressure gauge
Euro B/S171/0
1
4
6
3
5
Fig. E.16: Aqua sensor
Euro B/S 172/0GB_Pro
Pressure gauge
●
Refer to the important information
and initial preparation on page 45.
●
Release central heating water
pressure.
●
Pull out the four retaining clips and
remove the pressure gauge from
fascia.
●
Remove retaining clip and
disconnect pressure gauge
capillary tube.
●
Re-assemble in reverse order.
Aqua sensor
●
Refer to the important information
and initial preparation on page 45.
●
Release central heating water
pressure.
●
Remove the spring clip (
1
).
●
Undo union nut between the cold
water inlet service valve and aqua
sensor.
●
Remove the spring clip (
3
).
●
Pull the aqua sensor forward and
release cable.
●
Remove aqua sensor.
●
Remove the spring clip (
6
) and
disconnect blanking plate.
●
Re-assemble in reverse order.