17
Installation instructions geoTHERM VWS/VWW 0020057444_01
We recommend that the heat pump be transported with
the aid of a suitable barrow.
< 45°
Fig. 4.7 Transporting the complete unit (barrow)
a
Caution!
Risk of damage!
Find out the weight of the heat pump
from the Technical Data and make sure
that the transportation method you se-
lect is appropriately constructed.
When using a barrow, take note:
• Only use the barrow on the
rear
side of the heat
pump, as the weight distribution is then the most fa-
vourable.
• Fasten the heat pump with a restraining strap.
• Use a ramp when pushing the barrow from the pallet,
e.g. a batten and a sturdy board.
4.10
Installing the heat pump
0-10 mm
Fig. 4.8 Adjusting the feet
• Pay attention to the minimum wall clearances when
installing the heat pump (see Fig. 4.2).
• Align the heat pump horizontally by adjusting the feet.
Assembly and installation 4