Installer_manual_OEM_Vaillant_PROTO_3_GB - 06/11 - Vaillant
- 19 -
Key
1 Heat pump
2 Power supply and electrical protection for the heat pump (*)
3 Power supply and electrical protection for the DHW installation (*)
4 DHW time controller (optionnal) (*)
5 Relay mounting box (***)
5.1 Timer relay (connections terminals TR1 to TR6 depending on timer
relay datasheet) (***)
5.2 Auxilary power relay (connections terminals AR1 to AR6 depending
on Power relay datasheet) (***)
6 auroSTOR domestic water tank (**)
6.1 Electrical booster element
6.2 Cylinder Thermostat with integrated thermal cut out
6.3 Immersion heater with thermostat and intégrated thermal cut out
7 Command unit for the heat pump
8 Shut-off valve (*)
9 Differential bypass (*)
10 Expansion vessel (*) (if necessary)
11 Anti-sludge filter (*)
12 Safety valve (*)
13 Pressure-gauge (*)
14 3-channel valve (with return spring) for the domestic hot water tank,
L10 = domestic hot water position (*)
A flow heat pump circuit
b Return heat pump circuit
C flow domestic hot water
D Domestic cold water inlet
E
Return heating circuit
f
flow heating circuit
G Connection for filling heat pump circuit
H Discharge from the safety valve to a container for recovering glycol
water solution
(*) Not delivered with the appliance
(**) To find out the description of each auroSTOR components, see the
auroSTOR manual.
(***) for technical detail about these components see chapter " Hot
domestic water controller function and components description"
Application conditions in heating mode
-
Command unit used as room thermostat (see the chapter
"Appliance location"),
-
Installation with underfloor heating (< 53°C) or low-
temperature radiator (<60°C),
-
A single zone for regulating heating.
-
Minimum volume and flow of water for the installation (the
addition of a buffer tank is necessary if the volume of the
installation is less than the volume indicated in the table below):
geoTHERM
45/1 65/1 75/1 125/1 155/1
Minimum volume of the
installation (l)
14
21
28
42
49
Max volume of heat pump circuit,
without additional vessel, for
a water outlet temperature of
35°C (l)
65
65
65
95
95
Volume of water in the heat pump
1
1
1.2
2.3
2.3
Nominal water fl ow rate (m³/h)
0.7
1
1.2
2.1
2.5
i
If there is no buffer tank, the installation must not
contain thermostatic valves on all emitters, to ensure
that the minimum flow for the installation is provided
(see table above).
i
Highlighted cable section on electric diagram: 2.5mm².
For the dimensioning of the other cables and the
electrical protection on the appliances, see the chapter
"Electrical connection".
i
The back up heater must be equipped with an
overheat safety device with manual resseting the
overheat safety device must be approved according EN
60730-2-9 and his trigerring tested with and without
water inside the back up heater
Application conditions in Domestic hot water mode
i
Timer relay:
the time delay must be adjusted as follows:
- 30 mn for low inertia heating installation (radiators)
- 60mn for high inertia heating installation (floor
heating)
- For technical informations details and specific
adjustments about hot domestic water installation see
chapter "Domestic Hot water controler function and
components description"
i
To improve slightly Heat Pump working time the two
coils of Aurostor tank could be connected in series
Adjusting the heat pump's command unit
•
To find out the description of each function, see the chapter "Specific adjustment".
Menu
Name of the function
Value
factory setting
100
Type of system regulation
4
2
101
Configuration of the command unit
1
0
106
Configuration of the output between terminal channels 4 and N
1
1
112
External calibrated adjustment graphs
1 - 12
8
126
Configurations exterior sensor
2
2
148
Limit exterior temperature (T0)
-20°C
-20°C
150
Exterior temperature bivalence point (T1)
(To be defined) °C
0°C
151
Delays for switching on booster heating
20 minutes
20 minutes
152
Differential stop/start booster heating
5°C
5°C
153
Mode of activation hot-water demand contact S5
1
1
154
Functioning of booster heating
1
1
155
Functioning of main circulator
1
1
158
Differential on the temperature setting from the ambient air
0.3°C
0.3°C
INSTALLATION