Installer_manual_OEM_Vaillant_PROTO_3_GB - 06/11 - Vaillant
- 39 -
Code function
Description
Setting
factory
setting
Modifiable
parameter
Min
Max
13
Correction to the
ambient temperature
(command unit
position)
This parameter corrects the measurement of the ambient temperature following
an error in positioning the command unit.
-5°C
+5°C
0°C
Yes
14
Programme time
intervals
Choose the number of time intervals available for weekly programming:
1 = 2 time intervals
2 = 4 time intervals
3 = 6 time intervals
1
3
2
Yes
15
"Comfort" heating
temperature
Choose the ambient temperature in heating mode for the "Comfort" temperature. 12°C 38°C
20°C
Yes
16
"Comfort" cooling
temperature
Choose the ambient temperature in cooling mode for the "Comfort" temperature. 12°C 38°C
24°C
Yes
17
"Night" heating
temperature
Choose the ambient temperature in heating mode for the "Night" temperature.
12°C 38°C
18°C
Yes
18
"Night" cooling
temperature
Choose the ambient temperature in cooling mode for the "Night" temperature.
12°C 38°C
26°C
Yes
19
"Eco" heating
temperature
Choose the ambient temperature in heating mode for the "Eco" temperature.
12°C 38°C
15°C
Yes
20
"Eco" cooling
temperature
Choose the ambient temperature in cooling mode for the "Eco" temperature.
12°C 38°C
28°C
Yes
21
Ambient temperature
setting
This parameter displays the ambient temperature of the room where the
command unit is installed.
12°C 38°C
-
No
22
Displaying fault codes
Every second, this parameter displays the latest fault codes that appear.
-
-
-
No
23
Fault history
Every 4 seconds, this parameter displays the latest fault codes that appear.
-
-
-
No
15.2.4
Reinitialisation of parameters
This function is used to reinitialise the control box parameters
(factory settings).
b
The return to factory settings is irreversible. All the
personalised settings of the control box will be lost.
•
Press the 2 buttons ( ) and ( ) for 10 seconds.
When selecting for the fi rst time, the fi gure 999 appears in the
temperature display area and the fi gure 10 appears in the time
display area.
•
Hold down the ( ) button until 0 is displayed on the screen.
The message “FD” is displayed in the temperature area.
The control box then restores the factory default parameters.
•
Restart the entire system to complete the restore.