background image

eletronicVED pro series 

9

Water heater use and maintenance  6

Water heater use and maintenance

6�1 

Water heater use

 

Connect to water

After the water heater is installed, the water heater must first 

be drained and debris discharged.

When the outlet has continuous water flow, and there is no 

leakage at each joint, the appliance can be powered on.

 

Power on

Close the air switch (for the first time use

only after installation) and connect the main power. Press 

on/off button, the water heater display is bright and water 

heater is ready to start.

Note: the water heater can only heat when the flow rate is 

larger than 2.0L/ min and the tap water pressure exceeds 

0.1MPa.

 

Temperature selection

The outlet water temperature is constant, and the starting 

default temperature is 38℃.

Press temperature minus button, the temperature is 

decreased by 1℃.

The adjustable lowest temperature is 30℃.

Press temperature plus button, the temperature is increased 

by 1℃。The adjustable highest temperature is 60℃.

If there is no interruption of power supply, the temperature 

selected will show after power on/off.

 

Memory setting

While heating the water, press “M” button to use stored 

temperature setting.

Storage data: press “M” button during 3seconds. When 

temperature blinks on the display, the temperature can be 

adjusted by pressing temperature plus or minus button. 

After adjusting temperature, directly press “M” button to 

complete temperature setting. The buzzer will sound for 

every successful data storage.

 

Outlet water flow adjustment

Adjust outlet water flow by water flow adjustment knob. 

Clockwise rotation will reduce the water flow and anti-

clockwise will increase the water flow.

 

Power off

Press on/off button to turn off the appliance.

 

Maintenance

When detecting outlet water temperature sensor short circuit 

or open circuit, the display blinks and shows “E1”. The water 

heater stops working and needs maintenance.

When detecting inlet water temperature sensor short circuit 

or open circuit, the display blinks and shows “E2”. The water 

heater stops working and needs maintenance.

6�2 

Water heater maintenance

 

The water heater is only allowed to be repaired or 

maintained by qualified professionals. Improper operation 

will cause accidents or property loss.

 

Please cut off power before turning on water heater or 

doing maintenance of water heater.

 

Before maintenance, please refer to fault checklist for 

troubleshooting.

 

Keep the water heater clean before using.

 

The power supply must be cut off before cleaning the 

water heater. Use a damp cloth to dip a small amount 

of neutral detergent and gently wipe the water heater, 

please do not use gasoline or other solutions. Dry the 

water heater with a dry cloth and keep the water heater 

dry.

 

Take measures to prevent water heater from frozen if 

water heater does not work for a long time or the water 

heater is used in winter.

 

Water inlet filter needs regular cleaning.

Caution�

 

When the water heater is installed for the first 

time or reused again after reset, the users 

should turn off the power and open the tap 

first. The water heater can be powered on after 

the water flows smoothly without bubble or 

leakage. The default temperature is 38 ℃.

 

The water heater is heated only when the 

water flows and the flow rate is larger than   

2L/ Min.

 

When water heater is frozen or prone to 

be frozen, the water heater is forbidden to 

connect to the power. The water heater can be 

only used after it thaws.

Содержание EIWH electronicVED E 9/1-B IN

Страница 1: ... HOHFWURQLF9 SUR VHULHV 9 1 7R XVHUV SURIHVVLRQDOV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV ...

Страница 2: ...tructure and technical 5 4 1 Appliance structure 5 4 2 Electrical schematic diagram 5 4 3 Technical parameters 6 4 4 Dimention 6 5 Installation 6 5 1 Packing list 6 5 2 Special points related to installation 6 5 3 Installation schematic diagram 7 5 4 Installation 7 5 5 Function introduction 8 6 Water heater use and maintenance 9 6 1 Water heater use 9 6 2 Water heater maintenance 9 7 Troubleshooti...

Страница 3: ...ronicVED pro according to the instructions The rated voltage of the water heater is AV 220V and the rated frequency is 50Hz The product can provide prevention measures when grounding of water heater is abnormal When grounding is abnormal please stop using the water heater immediately unplug power plug or disconnect electric connection and call service hotline of the company immediately The water h...

Страница 4: ...c VED pro is kept in non heating area for a long time the water inside the appliance and pipe may be frozen in winter Consult about relevant requirements with a professional Please ensure that electronicVED pro is installed in normally frost free rooms Risk of damage caused by appliance modification It is not allowed to make modifications on electronicVED pro If there are failures If electronicVED...

Страница 5: ...erating instructions attached to the other components of the appliance These instructions are attached to the corresponding appliance components 2 1 Information storage Transfer necessary auxiliary tools to the appliance users Users are responsible for keeping them in order to use instructions and auxiliary tools as required 2 2 Scope of the instructions This instructions are only applicable to ap...

Страница 6: ...Mpa 0 75 Water resistance Ω cm 15 1300 Mini start flow L min 2 0 Waterproof type IP24 Net weight Kg 2 0 Dimension mm L W H 230 90 384 Water pipe connecting size G1 2 QOHW 2XWOHW QOHW ZLUH QOHW ZLUH 5 Installation 5 1 Packing list 5 2 Special points related to installation Install power supply and water piping according to the requirements Clean the pipe with water before installation to prevent re...

Страница 7: ...ld water 4 Slider 5 Flexible pipe 5HSUHVHQWV WKH ZDWHU SLSH KLGGHQ LQ WKH ZDOO 1 Hot water to basin 2 T cock 3 Angle valve or water mixing valve 4 Inlet cold water 5 Slider 6 Flexible pipe Warning Electric water heater must have stable grounding Earth wire is forbidden to connect to the neutral wire or water pipe Water heater is forbidden to connect to nonstandard tap or junction It is strictly pr...

Страница 8: ...ton to access the stored temperature setting Water flow adjust function adjust the outlet water flow by adjusting water flow adjust knob Over temperature protection function if the overheating temperature sensor detects that the temperature is over 80 heating will be stopped to enter the over temperature protection mode Power off is necessary to reset the appliance Fig 5 4 Panel structure Remark C...

Страница 9: ... flow and anti clockwise will increase the water flow Power off Press on off button to turn off the appliance Maintenance When detecting outlet water temperature sensor short circuit or open circuit the display blinks and shows E1 The water heater stops working and needs maintenance When detecting inlet water temperature sensor short circuit or open circuit the display blinks and shows E2 The wate...

Страница 10: ...ng power to the suitable water temperature The water is too cold Excessive water flow or low temperature of tap water Decrease the inlet water volume or Increase the powe When the water flow is too low the water heater does not start If the water volume is inadequate close the other water sources or add booster pump Voltage is instable or lower than the required product voltage Check the voltage b...

Страница 11: ......

Страница 12: ...ce Building Bhandarkar Road Lane 11 Deccan Pune 411 004 TEL 91 9619506391 cs aquagreensolutions in These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent ...