background image

eletronicVED pro series 

3

Safety  1

Safety

1�1 

Classification of action-related warnings

The action-related warnings are classified in 

accordance with the severity of the possible danger 

using the following warning signs and signal words:

Table 1.1 Warning symbols and symbol words

1�2 

Intended use

Vaillant EIWH electronicVED pro complies with 

current technology and safety requirements.

There is a risk of injury or death to the users or others, 

or of damage to the product and other property in 

the event if improper use or use for which it is not 

intended.

The appliance is not designed to be used by persons 

limited in physical, sensory or mental capacity 

(including children) or persons lacking experience and 

/ or knowledge unless there are guardians to explain 

how to use the equipment to those persons.

Children must be taken care of to ensure that they will 

not play with the appliance.

Vaillant EIWH electronicVED pro is only allowed to 

heat domestic water. Vaillant EIWH electronicVED 

pro is only suitable for household use of frost free 

closed indoor. Vaillant EIWH electronicVED pro is not 

intended as hot water circulation system.

Any other use that is not specified in these 

instructions, or use beyond that specified in this 

document shall be considered improper use. Any 

direct commercial or industrial use is also deemed to 

be improper. 

The manufacturer/supplier is not responsible for 

damage caused by improper use. The users also shall 

bear the risk alone.

Intended use including the following:

 - Observance of accompanying operating, 

installation and maintenance instructions for the 

product and any other system components

 - Compliance with all inspection and maintenance 

conditions listed in the instructions. 

1�3 

General safety information

Installation, operating, maintenance and repair

Only persons from professional company who 

are sufficiently qualified are allowed to conduct 

installation, commissioning, maintenance and repair of 

Vaillant EIWH electronicVED pro. It is only allowed to 

install Vaillant EIWH

 

electronicVED pro according to 

the instructions.

 

The rated voltage of the water heater is AV 220V, 

and the rated frequency is 50Hz.

 

The product can provide prevention measures 

when grounding of water heater is abnormal. 

When grounding is abnormal, please stop using 

the water heater immediately, unplug power plug 

or disconnect electric connection and call service 

hotline of the company immediately.

 

The water heater drained water (including the water 

heated by high temperature) is not allowed to be 

drunk directly.

 

Water heater electrical connection shall use 

dedicated sub circuit. Check whether the meter, 

circuit breaker and wire diameter match with the 

water heater. The power line diameter is no less 

than 4 mm² (8.8KW). The air-break switch is no 

less than 40A. Have a qualified electrician to check 

if necessary.

 

Please don’t use damaged wire, or aged, loose, 

unfixed power socket, otherwise will cause electric 

shock, short circuit, fire and other accidents

Risk of death from electric shock due to power 

supply wire and connector

When performing all operations on working appliance, 

especially on power supply wire and connector, there 

is risk of death caused by electric shock.

 

Only dealers and technicians that have been 

authorized by Vaillant may disassemble the 

appliance

 

If electronicVED pro fails to work normally, please 

contact the professional company

Risk of death from electric shock due to due to 

power supply wire and connector

The resistance of domestic water shall be no less than

1300Ω.cm(15 ℃),otherwise the appliance is not 

allowed to use.

 

Please first confirm the resistance and conductivity 

of the water with the local water supply company 

before the authorized professional install the 

appliance.

 

If you have any doubts about the water quality, 

please consult the professional.

Risk of scalding caused by hot water

The outlet temperature of hot water could be as high 

as 60℃.

 

When using electronicVED pro, please pay 

attention to the scalding risk caused by the high 

temperature of the outlet.

Warning 

symbols

Signal 

words

Explanation

Danger!

Imminent danger to life or risk of 

severe personal injury

Danger!

Risk of death from electric shock

Warning. Risk of minor personal injury

Caution. Risk of material or environmental 

damage

Содержание EIWH electronicVED E 9/1-B IN

Страница 1: ... HOHFWURQLF9 SUR VHULHV 9 1 7R XVHUV SURIHVVLRQDOV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV ...

Страница 2: ...tructure and technical 5 4 1 Appliance structure 5 4 2 Electrical schematic diagram 5 4 3 Technical parameters 6 4 4 Dimention 6 5 Installation 6 5 1 Packing list 6 5 2 Special points related to installation 6 5 3 Installation schematic diagram 7 5 4 Installation 7 5 5 Function introduction 8 6 Water heater use and maintenance 9 6 1 Water heater use 9 6 2 Water heater maintenance 9 7 Troubleshooti...

Страница 3: ...ronicVED pro according to the instructions The rated voltage of the water heater is AV 220V and the rated frequency is 50Hz The product can provide prevention measures when grounding of water heater is abnormal When grounding is abnormal please stop using the water heater immediately unplug power plug or disconnect electric connection and call service hotline of the company immediately The water h...

Страница 4: ...c VED pro is kept in non heating area for a long time the water inside the appliance and pipe may be frozen in winter Consult about relevant requirements with a professional Please ensure that electronicVED pro is installed in normally frost free rooms Risk of damage caused by appliance modification It is not allowed to make modifications on electronicVED pro If there are failures If electronicVED...

Страница 5: ...erating instructions attached to the other components of the appliance These instructions are attached to the corresponding appliance components 2 1 Information storage Transfer necessary auxiliary tools to the appliance users Users are responsible for keeping them in order to use instructions and auxiliary tools as required 2 2 Scope of the instructions This instructions are only applicable to ap...

Страница 6: ...Mpa 0 75 Water resistance Ω cm 15 1300 Mini start flow L min 2 0 Waterproof type IP24 Net weight Kg 2 0 Dimension mm L W H 230 90 384 Water pipe connecting size G1 2 QOHW 2XWOHW QOHW ZLUH QOHW ZLUH 5 Installation 5 1 Packing list 5 2 Special points related to installation Install power supply and water piping according to the requirements Clean the pipe with water before installation to prevent re...

Страница 7: ...ld water 4 Slider 5 Flexible pipe 5HSUHVHQWV WKH ZDWHU SLSH KLGGHQ LQ WKH ZDOO 1 Hot water to basin 2 T cock 3 Angle valve or water mixing valve 4 Inlet cold water 5 Slider 6 Flexible pipe Warning Electric water heater must have stable grounding Earth wire is forbidden to connect to the neutral wire or water pipe Water heater is forbidden to connect to nonstandard tap or junction It is strictly pr...

Страница 8: ...ton to access the stored temperature setting Water flow adjust function adjust the outlet water flow by adjusting water flow adjust knob Over temperature protection function if the overheating temperature sensor detects that the temperature is over 80 heating will be stopped to enter the over temperature protection mode Power off is necessary to reset the appliance Fig 5 4 Panel structure Remark C...

Страница 9: ... flow and anti clockwise will increase the water flow Power off Press on off button to turn off the appliance Maintenance When detecting outlet water temperature sensor short circuit or open circuit the display blinks and shows E1 The water heater stops working and needs maintenance When detecting inlet water temperature sensor short circuit or open circuit the display blinks and shows E2 The wate...

Страница 10: ...ng power to the suitable water temperature The water is too cold Excessive water flow or low temperature of tap water Decrease the inlet water volume or Increase the powe When the water flow is too low the water heater does not start If the water volume is inadequate close the other water sources or add booster pump Voltage is instable or lower than the required product voltage Check the voltage b...

Страница 11: ......

Страница 12: ...ce Building Bhandarkar Road Lane 11 Deccan Pune 411 004 TEL 91 9619506391 cs aquagreensolutions in These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent ...

Отзывы: