6
eletronicVED pro series
5 Installation
Warning�
▶
Water heater requires separate power
distribution, and electric meter capacity shall
be more than 80A.
▶
Power line path shall be no less than 4mm²
(8.8KW). The air-break switch shall be no
less than 40A.
▶
Good grounding
▶
Don’t install the water heater where directly
splashed by water
▶
Don’t install outdoor
▶
The water heater shall be installed strictly in
accordance with the drawing
EIWH
1 set
Manual
1 EA
Sealing washer
4 pieces
Screw
3 pieces
Expansion pipe
3 pieces
Filter
1 piece
4�3
Technical parameters
Table 4.1 Technical parameters
4�4
Dimention
Fig 4.3 Dimension drawing
Product type
VED E 9/1-B IN
Rated voltage (V)
Rated frequency (Hz)
220~/50
Rated power (kW)
8.8
Electrical current (A)
40
Temperature setting range (℃)
30~60
Rated pressure (Mpa)
0.75
Water resistance (Ω.cm)(15℃) ≥1300
Mini. start flow(L/min)
2.0
Waterproof type
IP24
Net weight(Kg)
2.0
Dimension (mm)
L*W*H
230×90×384
Water pipe connecting size
G1/2’’
,QOHW
2XWOHW
,QOHWZLUH
,QOHWZLU
H
5
Installation
5�1
Packing list
5�2
Special points related to installation
Install power supply and water piping according to the
requirements.
▶
Clean the pipe with water before installation to prevent
residual sediment from clogging the appliance
▶
The water heater shall be placed near power supply, floor
drain and water use point
▶
Water heater installation position shall be prevented from
any possible damage to articles caused by appliance
or pipe joint water leakage at adjacent areas or lower
floor. Don’t install the appliance outdoor or places easily
frozen. If the appliance is frozen, the container or pipe will
break, which lead to scalding accidents or water leakage.
▶
If water flow stops suddenly during working of water
heater, please turn off power to wait for smooth water
flow.
Содержание EIWH electronicVED E 9/1-B IN
Страница 11: ......