5  Installation

According to the reserved best installation position, please 

refer to the below points for installation.

 

Water pipe connection 

 - Remove the water heater front casing, confirm the 

position of the water heater and fix the water heater 

to the wall with screw on the basis of reserved water 

inlet and outlet positions.

 - Connect water heater and water inlet with double 

external thread inner joint.

 - After confirming good sealing of water heater 

waterway by water test, install weak current board 

connecting line and front casing.

 

Circuit installation

 - According to the reserved connecting cable, crimp the 

live wire and null wire to the corresponding binding 

post. Crimp the earth wire to the earth wire binding 

post.

5�5 

Function introduction

 

ON/OFF function: turn on and off the water heater

 

Water flow detection function: Water flow through the 

water heater is measured by a water flow sensor. if the 

water flow is higher than 2.0L/ min the water will be 

heated.

 

Constant temperature function: temperature control 

accuracy is ± 1 ℃,the overshoot is lower than 8%.

 

Memory function: press the "M" button to access the 

stored temperature setting.

 

Water flow adjust function: adjust the outlet water flow by 

adjusting water flow adjust knob.

 

Over temperature protection function: if the overheating 

temperature sensor detects that the temperature is 

over 80℃, heating will be stopped to enter the over 

temperature protection mode. Power off is necessary to 

reset the appliance.

Fig. 5.4 Panel structure
Remark

Caution�

 

The electrical connection has to be made 

after the water connection is finished

 

Before the water supply is connected to the 

water heater, the water should be released 

for about 20s, in order to evacuate the debris 

from the pipeline and to avoid blocking the 

water heater.

 

All newly installed or long time unused water 

heaters should be checked by water before 

they are put into use. Only after the water 

flow smoothly the water heater can be power 

on.

 

The water heater shall be connected directly 

to the dedicated line. The water heater 

must not be connected to a socket using an 

ordinary plug.

 

Water heater shall permanently be 

connected to the fixed wiring which can be 

fully disconnected.

 

Water heater shall permanently be 

connected to the fixed wiring which can be 

fully disconnected.

1  

Water flow adjust knob

2  Memory button
3  Temperature minus button
4  Temperature plus button
5  

Power supply on & off button

Содержание EIWH electronicVED E 9/1-B IN

Страница 1: ... HOHFWURQLF9 SUR VHULHV 9 1 7R XVHUV SURIHVVLRQDOV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV ...

Страница 2: ...tructure and technical 5 4 1 Appliance structure 5 4 2 Electrical schematic diagram 5 4 3 Technical parameters 6 4 4 Dimention 6 5 Installation 6 5 1 Packing list 6 5 2 Special points related to installation 6 5 3 Installation schematic diagram 7 5 4 Installation 7 5 5 Function introduction 8 6 Water heater use and maintenance 9 6 1 Water heater use 9 6 2 Water heater maintenance 9 7 Troubleshooti...

Страница 3: ...ronicVED pro according to the instructions The rated voltage of the water heater is AV 220V and the rated frequency is 50Hz The product can provide prevention measures when grounding of water heater is abnormal When grounding is abnormal please stop using the water heater immediately unplug power plug or disconnect electric connection and call service hotline of the company immediately The water h...

Страница 4: ...c VED pro is kept in non heating area for a long time the water inside the appliance and pipe may be frozen in winter Consult about relevant requirements with a professional Please ensure that electronicVED pro is installed in normally frost free rooms Risk of damage caused by appliance modification It is not allowed to make modifications on electronicVED pro If there are failures If electronicVED...

Страница 5: ...erating instructions attached to the other components of the appliance These instructions are attached to the corresponding appliance components 2 1 Information storage Transfer necessary auxiliary tools to the appliance users Users are responsible for keeping them in order to use instructions and auxiliary tools as required 2 2 Scope of the instructions This instructions are only applicable to ap...

Страница 6: ...Mpa 0 75 Water resistance Ω cm 15 1300 Mini start flow L min 2 0 Waterproof type IP24 Net weight Kg 2 0 Dimension mm L W H 230 90 384 Water pipe connecting size G1 2 QOHW 2XWOHW QOHW ZLUH QOHW ZLUH 5 Installation 5 1 Packing list 5 2 Special points related to installation Install power supply and water piping according to the requirements Clean the pipe with water before installation to prevent re...

Страница 7: ...ld water 4 Slider 5 Flexible pipe 5HSUHVHQWV WKH ZDWHU SLSH KLGGHQ LQ WKH ZDOO 1 Hot water to basin 2 T cock 3 Angle valve or water mixing valve 4 Inlet cold water 5 Slider 6 Flexible pipe Warning Electric water heater must have stable grounding Earth wire is forbidden to connect to the neutral wire or water pipe Water heater is forbidden to connect to nonstandard tap or junction It is strictly pr...

Страница 8: ...ton to access the stored temperature setting Water flow adjust function adjust the outlet water flow by adjusting water flow adjust knob Over temperature protection function if the overheating temperature sensor detects that the temperature is over 80 heating will be stopped to enter the over temperature protection mode Power off is necessary to reset the appliance Fig 5 4 Panel structure Remark C...

Страница 9: ... flow and anti clockwise will increase the water flow Power off Press on off button to turn off the appliance Maintenance When detecting outlet water temperature sensor short circuit or open circuit the display blinks and shows E1 The water heater stops working and needs maintenance When detecting inlet water temperature sensor short circuit or open circuit the display blinks and shows E2 The wate...

Страница 10: ...ng power to the suitable water temperature The water is too cold Excessive water flow or low temperature of tap water Decrease the inlet water volume or Increase the powe When the water flow is too low the water heater does not start If the water volume is inadequate close the other water sources or add booster pump Voltage is instable or lower than the required product voltage Check the voltage b...