Adapting the boiler to the heating installation
46
Installation and maintenance instructions ecoTEC 0020173113_01
11
Code
Parameters
Adjustable values
Factory
setting
Your own
setting
D.067
Remaining burner anti-cycling time
In minutes
Not adjustable
D.068
Unsuccessful ignitions at 1st attempt
Number of unsuccessful ignitions
Not adjustable
D.069
Unsuccessful ignitions at 2nd attempt
Number of unsuccessful ignitions
Not adjustable
D.070
Setting diverter valve position
0 = Normal mode
1 = Mid-position (parallel mode)
2 = Permanent heating setting
0
D.071
Target value maximum heating flow tem-
perature
40 to 80 °C
75 °C
D.072
Internal pump overrun after cylinder
charging
Not relevant
Not adjustable
D.073
Warm start target offset
Adjustable from -15 K to 5 K
0
D.075
Max. charging time for domestic hot
water cylinder without independent con-
trol system
Not relevant
Not adjustable
D.076
Device specific number
16 = VU 22
16 = VUW 26
Not adjustable
D.077
Limit on cylinder charging output
in kW
Not relevant
Not adjustable
D.078
Limit on cylinder charging temperature
in °C
Not relevant
Not adjustable
D.080
Operating hours, heating
In hours (h)
Not adjustable
D.081
Operating hours, hot water generation
In hours (h)
Not adjustable
D.082
Number of burner start-ups in heating
mode
Number of burner start-ups
Not adjustable
D.083
Number of burner start-ups in hot water
mode
Number of burner start-ups
Not adjustable
D.084
Maintenance indicator: Number of hours
until the next maintenance
Setting range: 0 to 3000 hrs and "---" for deactivated
"---"
D.088
Start delay for hot water draw-off detec-
tion via impeller (VUW boilers only)
0 = 1.5 l/min and no delay,
1 = 3.7 l/min and 2 sec. delay
0
D.090
Status of digital controller
1 = Recognised, 0 = Not recognised
Not adjustable
D.091
Status DCF with external sensor con-
nected
0 = No reception, 1 = Reception, 2 = Synchronised, 3 =
Valid
Not adjustable
D.092
actoSTOR module recognition
Not relevant
Not adjustable
D.093
Invalid device specific number (DSN)
Setting range: 0 to 99
D.094
Delete fault history
Delete fault list
D.095
Software version of PeBUS components
PCB (BMU)
Display (AI)
Not adjustable
D.096
Factory setting
Reset all adjustable parameters to default setting
11.1 Diagnosis codes (continued)