Appendix
0020244995_02
ecoTEC
pro
Installation
and
maintenance
instructions
47
K
Technical data
Technical data
–
General
VUW 246/5-
3 (H-GB)
ecoTEC pro
24
VUW 286/5-
3 (H-GB)
ecoTEC pro
28
VUW 286/5-
3 (P-GB)
ecoTEC pro
28
Designated country (des-
ignation in accordance
with ISO 3166)
GB (Great
Britain), IE
(Ireland)
GB (Great
Britain), IE
(Ireland)
GB (Great
Britain), IE
(Ireland)
Approved unit categories
II
2H3P
II
2H3P
II
2H3P
Gas connection, boiler
side
15 mm
15 mm
15 mm
Flow/return heating con-
nections, boiler side
22 mm
22 mm
22 mm
Hot and cold water con-
nection, boiler side
G 3/4
″
G 3/4
″
G 3/4
″
Expansion relief valve
connector (min.)
15 mm
15 mm
15 mm
Air/flue gas connection
60/100 mm
60/100 mm
60/100 mm
Condensate drain pipe-
work (min.)
19 mm
19 mm
19 mm
G20 natural gas flow
pressure
2.0 kPa
(20.0 mbar)
2.0 kPa
(20.0 mbar)
G31 propane gas flow
pressure
3.7 kPa
(37.0 mbar)
Gas flow rate at 15 °C
and 1013 mbar (based on
hot water generation, if
applicable), G20
2.5 m
³
/h
2.9 m
³
/h
Gas flow rate at 15 °C
and 1013 mbar (based on
hot water generation, if
applicable), G31
2.2 kg/h
Min. flue gas mass rate
(G20)
2.47 g/s
2.47 g/s
Min. flue gas mass rate
(G31)
3.49 g/s
Max. flue gas mass rate
10.8 g/s
12.6 g/s
12.6 g/s
Min. flue gas temperature
40
℃
40
℃
40
℃
Max. flue gas temperat-
ure
70
℃
70
℃
70
℃
Approved gas-fired units
C13, C33,
C43, C53
C13, C33,
C43, C53
C13, C33,
C43, C53
30% efficiency
109.4 %
109.4 %
108 %
NOx class
6
6
6
SEDBUK (2005)
A
A
A
SEDBUK (2009)
(G20/G31)
89.3 %
89.3 %
89.3 %
Boiler dimension, width
440 mm
440 mm
440 mm
Boiler dimension, height
720 mm
720 mm
720 mm
Boiler dimension, depth
338 mm
338 mm
338 mm
Approx. net weight
38 kg
38 kg
38 kg