2 Notes on the documentation
8
Installation
and
maintenance
instructions
ecoTEC
pro
0020244995_02
2
Notes on the documentation
2.1
Observing other applicable documents
▶
You must observe all the operating and installation in-
structions included with the system components.
2.2
Storing documents
▶
Pass these instructions and all other applicable docu-
ments on to the system operator.
2.3
Applicability of the instructions
These instructions apply only to:
Product article number
Article num-
ber
Gas Council
Number
VUW 246/5-3 (H-GB)
ecoTEC pro 24
0010021836
47-044-88
VUW 286/5-3 (H-GB)
ecoTEC pro 28
0010021837
47-044-89
VUW 286/5-3 (P-GB)
ecoTEC pro 28
0010021838
47-044-90
2.4
Benchmark
Vaillant is a licensed member of the Benchmark Scheme.
Benchmark places responsibilities on both manufacturers
and installers. The purpose is to ensure that customers are
provided with the correct equipment for their needs, that it is
installed, commissioned and serviced in accordance with the
manufacturer’s instructions by a competent person approved
at the time by the Health and Safety Executive and that it
meets the requirements of the appropriate Building Regu-
lations. The Benchmark Checklist can be used to demon-
strate compliance with Building Regulations and should be
provided to the customer for future reference.
Installers are required to carry out installation, commission-
ing and servicing work in accordance with the Benchmark
Code of Practice which is available from the Heating and
Hotwater Industry Council who manage and promote the
Scheme.
Benchmark is managed and promoted by the Heating and
Hotwater Industry Council.
For more information visit www.centralheating.co.uk
3
Product description
3.1
Product design
3.1.1
Functional elements, product with
integrated hot water generation
6
7
8
9
10
11
13
14
16
4
3
1
2
19
18
17
15
5
12
1
Gas valve
2
Water pressure sensor
3
Heat exchanger
4
Connection for the flue
pipe
5
Flue gas analysis point
6
Expansion vessel
7
Air intake pipe
8
Compact thermal
module
9
Ignition electrode
10
Fan
11
Automatic air vent
12
Pressure gauge
13
Internal pump
14
Diverter valve
15
Expansion relief valve
16
Electronics box
17
Impeller sensor (hot
water)
18
Bypass valve
19
Secondary heat ex-
changer
3.2
Information on the identification plate
The identification plate is mounted on the underside of the
product in the factory.
Information on the
data plate
Meaning
Read the instructions.
VUW…
Vaillant gas-fired wall-hung boiler for
heating and domestic hot water genera-
tion
..6/5-3
Gross calorific value power/product
generation equipment