Installation 5
0020244995_02
ecoTEC
pro
Installation
and
maintenance
instructions
15
5.8.2
Replacing the connection piece for the
air/flue pipe as required
1.
Replace the connection piece for the air/flue pipe as
required. The product-specific standard equipment is
listed under Technical data.
2.
Remove the connection piece for the air/flue pipe
–
this
is installed at the factory. (
→
Page 15)
3.
Alternatives 1 / 2
▶
If required, install the connection piece for the
air/flue pipe, 80/125 mm diameter. (
→
Page 15)
3.
Alternatives 2 / 2
▶
If required, install the connection piece with
offset for the air/flue pipe, 60/100 mm diameter.
(
→
Page 15)
5.8.2.1 Removing the connection piece for the
air/flue pipe
1.
2.
3.
1.
Insert a screwdriver into the slot between the measuring
stub pipes.
2.
Press the screwdriver carefully down
(1.)
.
3.
Turn the connection piece anticlockwise
(2.)
as far as it
will go and then remove it by pulling it upwards
(3.)
.
5.8.2.2 Installing the connection piece for the
air/flue pipe, 80/125 mm diameter
1.
Remove the connection piece for the air/flue pipe
–
this
is installed at the factory. (
→
Page 15)
2.
Insert the alternative connection piece. In doing so, pay
attention to the latching lugs.
3.
Turn the connection piece clockwise until it clicks into
position.
5.8.2.3 Installing the connection piece with offset
for the air/flue pipe, 60/100 mm diameter
1.
Remove the connection piece for the air/flue pipe
–
this
is installed at the factory. (
→
Page 15)
65 mm
1
2.
Insert the alternative connection piece with offset to-
wards the front.
3.
Use two screws
(1)
to secure the connection piece to
the product.
5.9
Electrical installation
The electrical installation must only be carried out by a quali-
fied electrician.
Danger!
Risk of death from electric shock!
Since mains connection terminals L and N re-
main live even if the on/off button is switched
off:
▶
Switch off the power supply.
▶
Secure the power supply against being
switched on again.
5.9.1
Opening the electronics box
▶
Open the electronics box as shown in the illustration.
5.9.2
Carrying out the wiring
Caution.
Risk of material damage caused by incor-
rect installation.
Mains voltage at incorrect terminals and plug
terminals may destroy the electronics.
▶
Do not connect any mains voltage to the
eBUS terminals (+/-).