Inspection and maintenance
60
Installation and maintenance instructions ecoTEC plus 0020116700_01
12
Settings
Unit
Natural gas (H)
Propane
CO
2
after 5 minutes full
load mode with
boiler front casing fitted
Vol.–%
7.8
-
10.2
9.7
-
10.7
CO
2
after 5 minutes full
load mode with boiler
front casing removed
Vol.–%
7.6
-
10.0
9.5
-
10.5
Set for Wobbe index Ws
kWh/m
3
15
22.5
CO value with full load
ppm
< 250
< 250
CO/CO
2
< 0.0031
< 0.0026
12.1
Factory gas setting
a
Danger!
Risk to life due to poisoning!
CO is an extremely toxic gas. Risk to life
due to excessive CO concentrations.
>
If you are not able to adjust the boiler
correctly and the flue gas values remain
higher than allowed in
¬ table 12.1
, call
the Vaillant Service Solutions (0870
6060 777).
>
Do not start up the boiler!
12.1.5
Performing the gas family check
a
Danger!
Risk to life due to poisoning!
CO is an extremely toxic gas. Risk to life
due to excessive CO concentrations. Fault
codes F.92 or F.93 may occur as result of
the gas family check.
>
Correct the failure unconditionally before
starting up the boiler for continuous
operation.
Menu ¬ Installer level ¬ Test programs ¬Gas family
check
The gas family check checks the boiler setting with regard
to combustion quality.
>
Perform the gas family check:
– as part of regular boiler maintenance
– after replacing components or working on the gas
route.
i
No CO/CO
2
or CO
2
measurement is possible dur-
ing the gas family check.
Result
Meaning
Response
F.92 Coding
resistance
fault
The coding
resistance on
the PCB does
not match the
entered gas
family
>
Check the coding resistance,
repeat the gas family check
and enter the correct gas fam-
ily.
"successful"
Combustion
quality is good.
Appliance con-
figuration
matches the
specified gas
family.
None
"Warning"
Combustion
quality insuffi-
cient. CO
2
value
and CO/CO
2
ratio are incor-
rect.
>
Start test program P.01 and
adjust the CO
2
value with the
adjusting screw in the venturi
¬ section 12.1.4
.
>
If the correct CO
2
value cannot
be set:
Check the gas restrictor for
correctness (yellow: H-gas,
grey: liquid gas) and damage.
>
Repeat gas family check.
F.93 Gas
group fault
Combustion
quality outside
the permitted
range
>
Damaged or incorrect gas
restrictor (yellow: H-gas, grey:
liquid gas), wrong gas group,
internal pressure measuring
point in venturi blocked (do not
use lubricants on O-ring in ven-
turi.), recirculation, faulty seal.
>
Resetting the boiler.
>
Set correct CO
2
value using
test program P.01 (adjusting
screw in venturi)
¬ section 12.1.4
.
>
Repeat the gas family check.
12.2
Results and measures after gas family check