Adapting the boiler to the heating installation
Installation and maintenance instructions ecoTEC plus 0020116700_01
51
11
Code
Parameters
Adjustable values
Factory
setting
Your own
setting
D.026
Auxiliary relay control
Circulation pump
External pump
Cylinder charging pump
Extractor hood
External solenoid valve
External fault message
Solar pump (not active)
eBUS remote control (not active)
Legionella protection pump (not active)
Solar valve (not active)
External
pump
D.027
Switching of relay 1 on the "2 in 7" multi-
functional module VR 40
Circulation pump
External pump
Cylinder charging pump
Extractor hood
External solenoid valve
External fault message
Solar pump (not active)
eBUS remote control (not active)
Legionella protection pump (not active)
Solar valve (not active)
External
pump
D.028
Switching of relay 2 on the "2 in 7"
multi-functional module VR 40
Circulation pump
External pump
Cylinder charging pump
Extractor hood
External solenoid valve
External fault message
Solar pump (not active)
Remote control eBUS (not active)
Legionella protection pump (not active)
Solar valve (not active)
External
pump
D.033
Fan speed target value
In rpm
Not adjustable
D.034
Fan speed actual value
In rpm
Not adjustable
D.035
Position of the diverter valve
Heating mode
Parallel operation
DHW mode
Not adjustable
D.036
Hot water flow quantity (impeller sen-
sor)
In l/min
Not adjustable
D.039
Solar feed temperature
Actual value in °C
Not adjustable
D.040
Flow temperature
Actual value in °C
Not adjustable
D.041
Return temperature
Actual value in °C
Not adjustable
D.044
Digitised ionisation value
Display range 0 to 1020,
> 800 no flame
< 400 good flame
Not adjustable
D.046
Pump type
Relay with disable facility
PWM with disable facility
Relay with
disable facility
D.047
Outside temperature (with weather-con-
trolled Vaillant controller)
Actual value in °C
Not adjustable
D.050
Offset for minimum speed
In rpm, setting range: 0 to 3000
Nominal value
set in factory
D.051
Offset for maximum speed
In rpm, setting range: -990 to 0
Nominal value
set in factory
D.058
Activation of solar post-heating for VUW
boilers;
Switch hot water mode
Solar post-heating mode deactivated
DHW activation target value minimum 60 °C
Solar post-
heating mode
deactivated
11.1 Diagnosis codes (continued)