45
Troubleshooting 8
Instructions for installation and servicing ecoMAX
45
Key to status codes
Code
Meaning
ecoMAX 600
ecoMAX 800
S.0
No heat demand (heating operation)
X
X
S.1
Pump running (heating operation)
X
X
S.2
Pump running – pre ignition (heating operation)
X
X
S.3
Ignition sequence (heating operation)
X
X
S.4
Burner ignited (heating operation)
X
X
S.5
–
S.6
Heating system fan over run
X
X
S.7
Pump over run (heating operation)
X
X
S.8
Anti cycling mode (heating operation)
X
X
S.10
Hot water demand (hot water operation)
X
S.11
Pump and fan running (hot water operation)
X
S.13
Ignition sequence (hot water operation)
X
S.14
Burner ignited (hot water operation)
X
S.15
–
S.16
Fan over run (hot water operation)
X
S.17
Pump over run (hot water operation)
X
S.20
Warmstart demand (warm start)
X
S.21
Pump and fan running (warm start)
X
S.23
Ignition sequence (warm start)
X
S.24
Burner ignited (warm start)
X
S.25
–
S.26
Hot–water fan over run
X
S.27
Pump over run (warm start)
X
S.28
Anti cycling mode (warm start)
X
S.30
No heating demand from external controls
X
X
S.32
Fan unit waiting period
X
X
S.34
Frost protection mode
X
X
S.36
No heating demand from low voltage controls
X
X
S.37
Fan unit waiting period
X
X
S.39
Contact thermostat has been activated (under floor systems)
X
X
S.53
Delay mode due to lack of water in system (~20 mins.)
X
X
S.54
Low water–level waiting period
X
X
Table 8.1 Status codes
83 41 77_12 GB04.04.qxd 22.09.2004 12:34 Uhr Seite 45