background image

Operating

Manual

Easypell
16 — 32kW

ENGLISH

200013_EN 2.0

·

www.easypell.com

Содержание Easypell

Страница 1: ...Operating Manual Easypell 16 32kW ENGLISH 200013_EN 2 0 www easypell com...

Страница 2: ...N 2 0 Version valid from 01 2018 Approved Wohlinger Christian Author Eco Engineering 2050 GmbH A 4132 Lembach M hlgasse 9 Tel 43 0 72 86 74 50 Fax 43 0 72 86 74 50 10 E Mail office easypell com by Eco...

Страница 3: ...lets as per EN ISO 17225 2 class A1 11 7 The Easypell 12 8 Maintenance and servicing 14 8 1 Maintenance 14 8 2 Emptying the ash pan 14 8 3 Cleaning the boiler every year 16 9 Operating the heating sys...

Страница 4: ...read this manual right through and take note of the safety warnings Keep all documentation supplied with this unit in a safe place for future reference Please pass on the documentation to the new user...

Страница 5: ...em is designed to heat water for central or other indirect heating systems and hot water supply for buildings It is not permissible to use the pellet heating system for any other purpose Reasonable fo...

Страница 6: ...n that could lead to death or life threatening injury Warning indicates a situation that could lead life threatening or serious injury Caution indicates a situation that could lead to injury Note indi...

Страница 7: ...s supplied with suffi cient combustion air The openings in the combustion air inlet must never be partially or completely closed Ventilation systems central vacuum cleaning systems extractor fans air...

Страница 8: ...t heating system using pellets that comply with EN ISO 17225 2 class A1 only Damage to property Do not use the heating system if it or any of its compo nents come into contact with water If water dama...

Страница 9: ...ining chlorine nitrobenzene or halogen in the room where the heating system is installed if combustion air is drawn directly from the room Do not hang out washing in the central heating room Prevent d...

Страница 10: ...must be within 1 metre of the boiler Safety temperature sensor The pellet boiler is equipped with a safety temperature sensor This is located on the pel let boiler If the boiler temperature exceeds 95...

Страница 11: ...ntent max 10 Specification for high quality pellets as per EN ISO 17225 2 class A1 Ash content max 0 7 Length max 40 mm Diameter 5 7 mm Fine material max 1 Contents 100 natural wood The heating system...

Страница 12: ...6 20 25 and 32kW Note Refer to the data plate for the power rating of your Easypell The data plate is located on the rear side of the boiler Here you find the type designation manufacturer s serial nu...

Страница 13: ...tion fan 2 Flame tube 8 Anti blowback system 3 Heat exchanger 9 Burner auger 4 Boiler water 10 Electronic ignition 5 Boiler insulation 11 Combustion chamber sensor 6 Combustion chamber cover 12 Ash bo...

Страница 14: ...should be placed in a metal steel container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or ground well away from all combustible materials pending...

Страница 15: ...Emptying the ash pan 15 Operating Manual Easypell 16 32kW...

Страница 16: ...the boiler until it has been allowed to cool down Switch off the heating system at least 6 hours before opening the boiler Switch off the main switch before starting any mainte nance work on the syst...

Страница 17: ...Cleaning the boiler every year 17 Procedure for cleaning the boiler Operating Manual Easypell 16 32kW...

Страница 18: ...18 Cleaning the boiler every year Reduction in boiler performance and damage to pellet boiler due to blockages in the air inlet Clean the air intakes the burner plate and the flame tube 200013_EN 2 0...

Страница 19: ...Cleaning the boiler every year 19 Cleaning the Induced draft blower Operating Manual Easypell 16 32kW...

Страница 20: ...oom and storage room Fire risk Keep the ash removal door closed while the boiler is in operation 9 1 Description of the control panel The control panel is located in the boiler front cover 1 Safety te...

Страница 21: ...function is selected the value can be changed by pressing the arrow keys When this function is selected you leave the menu without saving the changed value Icons System status Icon view Description R...

Страница 22: ...has released Container cover is open OFF Ignition Sensor break boiler sensor Sensor break combustion chamber sensor Flame return gate open fault Time programme aktive Burner contact closed Pump activ...

Страница 23: ...protection device is opened This symbol appears on the display while the fire protec tion device is being opened approx 2 minutes button After the fire protection device has been opened the ig nition...

Страница 24: ...es the symbol for heating at full power appears The boiler is now heating at full power button Display of the current boiler temperature button Adjusting the time programme of the boiler By pressing t...

Страница 25: ...nimum boiler rating Adjustment range max rated power 10 C bis 6 C Adjustment range min power 7 C bis 25 C button Setting current time Press and to set the current time Confirm with button Display of c...

Страница 26: ...s The fire protection device is opened This symbol appears on the display while the fire protec tion device is being opened approx 2 minutes button After the fire protection device has been opened the...

Страница 27: ...s can last up to 15 minutes the symbol for heating at full power appears The boiler is now heating at full power button Display of the current boiler temperature button Display of the current DHW temp...

Страница 28: ...the time programm of the DHW By pressing the start and stoptime appear Activate the times with button Setting Outertemperature control Here you can set the temperature values for the maxi mum and mini...

Страница 29: ...time Press and to set the current time Confirm with button Display of current boiler status 1 Current boiler temperature 3 Current DHW temperature 2 Boiler set temperature 4 DHW set temperature Opera...

Страница 30: ...s The fire protection device is opened This symbol appears on the display while the fire protec tion device is being opened approx 2 minutes button After the fire protection device has been opened the...

Страница 31: ...l for heating at full power appears The boiler is now heating at full power button Display of the current boiler temperature button Setting the time programm of heating circuit 1 By pressing the start...

Страница 32: ...t 2 By pressing the start and stoptime appear Activate the times with button Setting the time programm of heating circuit 3 By pressing the start and stoptime appear Activate the times with button Dis...

Страница 33: ...rogramm of the DHW By pressing the start and stoptime appear Activate the times with button Setting Outertemperature control Here you can set the temperature values for the maxi mum and minimum boiler...

Страница 34: ...et the current time Confirm with button Display of current boiler status 1 Heating circuit 1 5 Boiler set temperature 2 Heating circuit 2 6 Current DHW temperature 3 Heating circuit 3 7 DHW set temper...

Страница 35: ...protection device is opened This symbol appears on the display while the fire protec tion device is being opened approx 2 minutes button After the fire protection device has been opened the ig nition...

Страница 36: ...e symbol for heating at full power appears The boiler is now heating at full power button Display of the current boiler temperature button Adjusting the time programme of the heating circuit 1 By pres...

Страница 37: ...uit 2 By pressing the start and stoptime appear Activate the times with button Display of the current DHW temperature button Setting the DHW set temperature The DHW set temperature can be set in the r...

Страница 38: ...pressing the start and stoptime appear Activate the times with button Display current accumulator temperature button Setting the accumulator set temperature The accumulator set temperature can be set...

Страница 39: ...and to set the current time Confirm with button Display of current boiler status 1 Heating circuit 1 7 Accumulator set temperature 2 Heating circuit 2 8 Current boiler temperature 3 DHW 9 Boiler set...

Страница 40: ...s The fire protection device is opened This symbol appears on the display while the fire protec tion device is being opened approx 2 minutes button After the fire protection device has been opened the...

Страница 41: ...or heating at full power appears The boiler is now heating at full power button Display of the current boiler temperature button Adjusting the time programme of the heating circuit 1 By pressing the s...

Страница 42: ...HW By pressing the start and stoptime appear Activate the times with button Display current accumulator temperature button Setting the time programm of the DHW By pressing the start and stoptime appea...

Страница 43: ...ator set temperature can be set in the ran ge of 30 C to 75 C button Setting Outertemperature control Here you can set the temperature values for the maxi mum and minimum boiler rating Adjustment rang...

Страница 44: ...la tor temperature 8 Boiler set temperature 4 currently deman ded accumulator set temperature from the boiler depending on cur rent demand 9 Current DHW temperature 5 Pump on temperature 10 DHW set te...

Страница 45: ...Setting the time program 45 The value can be raised or lowered by pressing the keys button save value Operating Manual Easypell 16 32kW...

Страница 46: ...46 Setting the time 10 7 Setting the time The current time is displayed Note The setting of the time is analog to the setting of the time programes 200013_EN 2 0...

Страница 47: ...The system restarts automatically when the cause has been eliminated Overview of malfunction alarm texts Display Error code 0 Description Boiler sensor fracture measuring circuit from boiler sensor is...

Страница 48: ...signal below 0V combustion chamber leak check closure of boiler door Error code 5 Description Negative draft input short circuit measuring circuit from negative draft measu rement is shorted out Cause...

Страница 49: ...ate and ignition tube Combustion chamber sensor contaminated clean combustion chamber sensor and fcombus tion chamber tube Combustion chamber sensor is not inserted in to tube insert combustion sensor...

Страница 50: ...re measuring circuit from DHW sensor is open Cause and Remedy sensor not connected connect sensor at input sensor defect measure sensor approx 2k at 25 C replace if required sensor cable defect replac...

Страница 51: ...escription Accumulator sensor short circuit measuring circuit from acculmulator sensor is shorted out Cause and Remedy sensor defect measure sensor approx 2k at 25 C replace if required sensor cable d...

Страница 52: ...ir work on this system Use original Eco Engineering spare parts only Not using original Eco Engineering spare parts will cause the warranty to become void 11 5 Checking the central heating room Checki...

Страница 53: ......

Страница 54: ...uthor Eco Engineering 2050 GmbH A 4132 Lembach M hlgasse 9 Tel 43 0 72 86 74 50 Fax 43 0 72 86 74 50 10 E Mail office easypell com by Eco Engineering 2050 GmbH www easypell com Subject to modifcations...