Safety information and regulations

4

ecoLEVEL installation and maintenance instructions  0020029316_01 

2

The condensed water pump is not suitable for the pumping 
of other fluids or solid media. In particular, waste water of 
all types, chemicals and emulsions that contain oil must not 
be fed into the condensed water pump. Using the con-
densed water pump in vehicles is regarded as improper use. 
Units that are not classed as vehicles are those that are 
installed in a fixed and permanent location (known as "fixed 
installation"). 
Any other use, or use beyond that specified, shall be con-
sidered improper use. Any direct commercial or industrial 
use is also deemed to be improper. The manufacturer/sup-
plier is not liable for any claims or damage resulting from 
improper use. The user alone bears the risk.
Intended use includes observance of the operating and 
installation and maintenance instructions and all other 
applicable documents, as well as adherence to the mainte-
nance and inspection conditions.

Caution.

Improper use of any kind is prohibited.

2.2  

General safety information

Working on the ecoLEVEL condensed water pump

The ecoLEVEL condensed water pump

 

must only be 

installed and started up by a competent person. The exist-
ing regulations, rules and guidelines must be observed 
when doing so. Inspection/maintenance and repairs must 
also be carried out by this skilled tradesman.
Only competent persons who have acquainted themselves 
with all the safety information provided in these installation 
instructions, and the fitting, operating and maintenance 
instructions, may work on this unit.

Risk of electric shock when opening the unit and 
carrying out maintenance work.

When operating this unit, certain components must inevita-
bly be under dangerous voltages which can lead to severe 
bodily injury or to death.

 

>

Ensure that the unit is only opened by a company oper-
ating a recognised competent persons scheme.

 

>

Only open the bottom cover plate if all electrical connec-
tions to the pump have been isolated. 

 

>

Before carrying out any visual inspections and mainte-
nance work, ensure that the power supply is switched off 
and secured against being switched back on again. 

Risk of electric shock when the unit is switched on.

When operating this unit, certain components must inevita-
bly be under dangerous voltages which can lead to severe 
bodily injury or to death.

 

>

If measurements need to be made with the power supply 
switched on, never touch the electrical connections.

 

>

Remove all jewellery from wrists and fingers.

 

>

Make sure that the test equipment is in a good, safe 
operating condition.

 

>

When working on the unit when it is switched on, ensure 
that it is standing on an insulated base, in other words 
make sure that there is no earth connection.

Risk of burns and explosion when unsuitable 
 liquids are used.

Pumping out flammable and explosive liquids such as pet-
rol, heating oil, etc., poses a risk of burns and explosions. 

 

>

Do not use the pump to pump out flammable or explo-
sive liquids.

Risk of explosions in explosive atmospheres.

Operating the pump in explosive atmospheres could trigger 
an explosion.

 

>

Do not use the pump in an explosive atmosphere.

Risk of injury due to condensate.

The condensate pumped by the pump poses a risk to the 
eyes if they come into contact with it. 

 

>

Avoid any contact of the condensed water with the eyes.

 

>

Make sure that the ecoLEVEL condensed water pump is 
only operated out of the reach of children.

 

>

In case of eye contact with the condensate, rinse the 
eyes thoroughly with clean water and seek medical 
advice.

Danger of poisoning by flue gas leaks.

If you connect the condensate drain hose of the pump with 
the waste water piping, the internal siphon of the boiler 
may be completely emptied.

 

>

Do not connect the water condensate hose of the pump 
with a sealed connection to the waste water piping ('free 
outlet').

Malfunctions and material damage due to 
 instability.

If the pump is not in a stable position during operation, this 
can lead to malfunctions of the pump. This may result in 
damage to the pump or boiler.

 

>

During operation, ensure that the pump has a stable 
base or is attached to the wall.

Risk of damage due to improper modifications.

Modifications to the ecoLEVEL condensed water pump may 
damage the unit and are therefore generally prohibited.

 

>

Under no circumstances should you ever attempt to make 
alterations to the pump or other parts of the  system.

 

>

Consult an approved heating specialist company to make 
such alterations.

Material damage caused by leaking condensed 
water

In the event of a defect in the condensed water pump, leak-
ing condensed water may cause material damage or dam-
age to the boiler.

 

>

Connect a current interrupter or an alarm to the safety 
cut-out switch.

Содержание ecoLEVEL

Страница 1: ...Installation and maintenance instructions For the competent person GB IE Installation and maintenance instructions ecoLEVEL Condensed water pump ...

Страница 2: ...g and positioning the drain hose 9 4 4 Connecting the drain hose to the existing discharge pipe 10 4 5 Connecting the condensed water pump to the boiler 11 5 Electrical connection 12 5 1 Overview of the electrical connections 12 5 2 Preparing the electrical connection 12 5 3 Connecting the condensed water pump to the 230 V mains voltage 12 5 4 Connecting the condensed water pump to the safety cut ...

Страница 3: ...e ecoLEVEL condensed water pump 2 Safety information and regulations Classification of warnings The warnings are classified in accordance with the severity of the possible danger using the following warning signs and signal words Warning symbol Signal word Explanation a Danger Imminent danger to life or risk of severe personal injury e Danger Risk of death from electric shock a Warning Risk of min...

Страница 4: ...n components must inevita bly be under dangerous voltages which can lead to severe bodily injury or to death If measurements need to be made with the power supply switched on never touch the electrical connections Remove all jewellery from wrists and fingers Make sure that the test equipment is in a good safe operating condition When working on the unit when it is switched on ensure that it is sta...

Страница 5: ...nnection Make sure that the power supply is earthed in accordance with legal requirements Regulations and standards IEC 60364 7 712 Electrical installations of buildings Part 7 712 EMC test procedure in accordance with EN 50081 1 1992 EN 50082 1 1997 Interference emission EN 55014 1 1993 Immunity EN 55014 2 1997 Rules of engineering The installation must suit the conditions at the site of the cust...

Страница 6: ...erial 1 10 Inlet hose dia 24 mm x 1 15 m 1 Wall bracket for drain hose 6 3 1 Scope of delivery 3 2 Required tools The following tools are required for installation Drill Drill bit 6 mm Flat blade screwdriver Spirit level Cutting blade Tools for electrical connection 3 3 Selecting the installation site The ecoLEVEL condensed water pump is designed for installation in the room housing the boiler The...

Страница 7: ...and installation clearances During installation adhere to the appropriate dimensions and installation clearances 3 5 Installing the wall bracket A B 3 3 Installing the wall bracket Push the pre assembled wall bracket downwards out of the casing for the condensed water pump Install the wall bracket in a suitable position underneath the condensate drain point of the boiler The wall bracket must be i...

Страница 8: ...over b Caution Material damage If the inlet hose is not connected correctly the condensed water cannot flow freely into the pump Route the inlet hose at a constant down ward gradient from the boiler to the ecoLEVEL condensed water pump Lay the inlet hose as straight as possible avoiding any bends or kinks 4 1 Removing the ecoLEVEL 1 3 5 4 2 4 1 Removing the non return valve and cover and installin...

Страница 9: ...vel Note that the hoses must be pushed no more than 3 notches into the inlet openings 3 and 4 Replacing the cover Place the cover onto the ecoLEVEL condensed water pump from above 4 3 Connecting and positioning the drain hose Connecting the drain hose Push the drain hose fig 3 1 item 5 onto the removed non return valve fig 3 3 item 1 until it stops Insert the non return valve into the cover and lo...

Страница 10: ...he existing discharge pipe i Note If a 21 5 mm discharge pipe is already present you can use the supplied pipe connecting ele ments 1 4 3 Drain hose and stainless steel pipe insert not installed Shorten the end of the drain hose 1 For this ensure that the cut on the hose is at a right angle and is free from burrs fig 4 3 1 2 4 4 Drain hose and stainless steel pipe insert installed Hold the cut end...

Страница 11: ...tion 2 and the coupling piece 3 together fig 4 6 4 5 Connecting the condensed water pump to the boiler The ecoLEVEL condensed water pump can be connected to the siphon of all Vaillant condensing boilers using the inlet hose provided If the boiler s condensed water drain hose is long enough it can be connected directly to the pump fig 4 1 fig 4 2 If the boiler hose is too short replace it with the ...

Страница 12: ...can be connected 2 Main line from ecoLEVEL 3 Connection cable for the safety cut out switch with Pro E plug and X 40 plug The 230 V connection cable 1 with the free cable end pro vides the power supply to the pump The connection cable of the safety cut out switch 3 is used for the electrical connection of the safety cut out switch to the boiler 5 2 Preparing the electrical connection Before you es...

Страница 13: ...witch to the extra low voltage circuit of the boiler using variants I II or III 1 Anl Therm 24V RT BUS Burner off 24V RT BUS 2 2 5 2 Connecting the safety cut out switch connection type A Variants I and II Open the electronics box on the boiler On the boiler PCB remove the plug from the blue socket which is labelled as either Anl Therm I or Burner off B Off II 1 Instead plug the Pro E plug on the ...

Страница 14: ...pied If this is the case connect the safety cut out switch as follows Insert the plug in the connection X40B of the multi func tional module 2 of 7 Also refer to the instructions for the multi functional module If a flue non return flap is connected to the multi functional module 2 in 7 and you want to use the function of the flue non return flap you must not use the X40B connection In this case u...

Страница 15: ...e maximum permitted value The safety cut out switch is triggered if this condition is prolonged If a connection between the safety cut out switch and the boiler has been installed the boiler is switched off Switching off prevents further con densed water from form ing 4 Flashes green Flashes red The pump is at rest for a defined time period and then starts up again on its own 5 Flashes green Flash...

Страница 16: ...our unit To eliminate the fault refer to the installation instruc tions for your boiler or system Connection for safety cut out switch Message if fault occurs Connection type A Status message on unit display S 39 Connection type B Status message on unit display S 42 approx 15 min fault message F 77 6 3 Fault messages divided according to the connection type 7 Handing over to the operator The opera...

Страница 17: ...e In doing so protect against leaking condensed water For more information see the Safety section section 2 Remove the non return valve 1 from the pump cover by turning it anti clockwise 1 4 3 2 3 8 2 Removing the sealing insert Removing the sealing insert from the non return valve Proceed carefully when removing the sealing insert Ensure that the sealing insert is not damaged To remove the sealin...

Страница 18: ...or cleaning agents which could damage the plastic casing Reassemble the unit Place the O ring 2 onto the internal component 1 as shown Place the internal component 1 back into the conden sate vessel Ensure that the clips click into place Replace the pump cover on the unit 9 Spare parts Procuring spare parts The original components of the unit were also certified as part of the CE declaration of co...

Страница 19: ...priate service agreement Terms and conditions do apply to the guarantee details of which can be found on the registration card included with this appliance In order to qualify for guarantee after one year the appliance must be serviced in accordance with our installation manual servicing instructions The benchmark service history should be completed Note all costs associated with this service are ...

Страница 20: ... nominal output W 25 Max feed height m 4 Dimensions Height mm 150 Width mm 175 Depth mm 100 Weight when filled with water kg 1 8 Inlet hose max outside diameter mm 24 Drain hose min inner diameter mm 10 Water inlet temperature C 1 60 Ambient temperature C 5 60 Safety Radio shielded non interacting with the mains supply Safety cut out switch 5 mA 4 A 230 V Level of protection in accordance with EN ...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...0020029316_01 GBIE 102012 Subject to change Manufacturer Supplier ...

Отзывы: