Appendix
48
Installation and maintenance instructions ecoCOMPACT 0020181421_04
Code Parameter
Values or explanations
Default
setting
User-spe-
cific setting
D.074 Anti-legionella function
0 = Off
1 = On
Thermal disinfection is carried out every 24 hours
0 = Off
D.075 Maximum charging time for the
domestic hot water cylinder
20 - 90 min
45 mins
D.076 Device specific number
Unit variant display (DSN)
Not ad-
justable
D.077 Limit on cylinder charging output in
kW
Adjustable cylinder charging output in kW
D.078 Max. flow temperature during post-
heating of the cylinder
Adjustable cylinder charging output in kW
50 … 80
℃
75
℃
D.080 Operating hours of the burner in
heating mode
In hours (h)
Not ad-
justable
D.081 Operating hours of the burner for
domestic hot water generation
In hours (h)
Not ad-
justable
D.082 Number of burner start-ups in heat-
ing mode
Number of burner start-ups
Not ad-
justable
D.083 Number of burner starts in domestic
hot water mode
Number of burner start-ups
Not ad-
justable
D.085 Minimum unit output
In kW
Not ad-
justable
D.090 Status of the digital eBUS control
Recognised, not recognised
Not ad-
justable
D.091 Status of DCF with outdoor temper-
ature sensor connected
No reception
Reception
Synchronised
Valid
Not ad-
justable
D.093 Unit variant setting (DSN)
Adjustment range: 100 to 199
The three-digit DSN code is located on the product's
data plate.
D.094 Delete fault history
Delete fault list
0 = No
1 = Yes
D.095 Software version of PeBUS compon-
ents
PCB (BMU)
Display (AI)
Solar card (SMU)
Not ad-
justable
D.096 Default setting
Reset all adjustable parameters to factory setting
0 = No
1 = Yes
D.098 Value of coding resistors for gas
group and output range
Display xx.yy
xx = Coding resistor 1 in cable harness for output range:
08 = Up to 25 kW
09 = up to 30 kW
10 = up to 34 kW
yy = Coding resistor 2 on PCB for gas type (read gas
category of the unit):
02 = P gas or G31
03 = E gas or G20
07 = L gas or G25
Not ad-
justable
D.121 Enriching the air/gas mixture at min.
output
0 = Normal
1 = Enriched
2 = Slightly enriched
0 = Normal
D.122 Limited available pressure
In mbar, for proKlima only
D.123 Time cylinder was last charged
min
Not ad-
justable
D.124 Domestic hot water cylinder in ECO
mode
0 = Function deactivated
1 = ECO mode activated
0 = Function
deactivated
Not ad-
justable
D.125 Domestic hot water temperature at
the cylinder outlet
Actual value in °C
Not ad-
justable