Start-up 7
0020181421_04 ecoCOMPACT Installation and maintenance instructions
19
7.2
Checking the factory setting
Applicability:
Except Belgium
Caution.
Risk of material damage caused by mak-
ing unauthorised settings.
▶
Never modify the factory setting of the gas
pressure regulator of the gas valve.
Note
Each destroyed seal must be restored.
1
Note
Some units are equipped with gas valves that
have no pressure regulator
(1)
.
Caution.
An incorrect gas group setting may cause
operating faults or a reduction in the ser-
vice life of the product.
If the product design does not match the local
gas group, malfunctions will occur or you will
have to replace product components prema-
turely.
▶
Before you start up the product, compare
the gas group information on the data
plate with the gas group available at the
installation site.
The product's combustion has been factory tested and is
preset for operation with the gas group indicated on the iden-
tification plate.
Conditions
: The product design
is not compatible
with the local gas
group
▶
Do not start up the product.
▶
Change the type of gas in accordance with your system.
Conditions
: The product design
is compatible
with the local gas group
▶
Proceed as described below.
7.3
Filling the condensate siphon
Danger!
Risk of poisoning due to escaping flue
gas.
An empty or insufficiently filled condensate
siphon may allow flue gas to escape into the
room air.
▶
Fill the condensate siphon with water be-
fore starting up the product.
1
1.
Remove the lower section of the siphon
(1)
by turning
the bayonet fitting anti-clockwise.
2.
Fill the lower section of the siphon with water up to 10
mm below the upper edge.
3.
Screw the lower section back onto the condensate si-
phon correctly.
7.4
Switching on the product
▶
Press the on/off button on the product.
◁
The basic display appears on the display.
7.5
Running the installation assistants
The installation assistant is displayed whenever the product
is switched on until it has been successfully completed.
It provides direct access to the most important check
programmes and configuration settings for starting up the
product.
Confirm the launch of the installation assistant. All heating
and domestic hot water demands are blocked whilst the in-
stallation assistant is active.
Confirm that you want to navigate to the next point by press-
ing
Next
.
If you do not confirm the launch of the installation assistant,
it is closed 10 seconds after you switch on the unit and the
basic display then appears.