Manual - Solar hot water systems 0020009607_02
10
Technical data, tube collectors
Appliance designation
Units
auroTHERM exclusive VTK 570
Surface area (gross, aperture/net)
m
2
1,28 / 0,82
Height mm
1695
Width mm
790
Depth mm
100
Weight kg
20
Collector capacity
l
3,56
Copper pipe connection, flat-face
Thread
3/4“
Insulation: high-vacuum
bar
10
-6
Max. operating pressure
bar
6
Spiegel Reinsilber, Reflexionsgrad
ρ
%
94
±
1
Absorber emission
ε
%
5
±
2
Absorber absorption
α
%
95
±
1,0
Solar sensor sleeve
∅
mm
6
CE label
0036
Shutdown temperature (according to prEN 12975-2,
c < 1 m/s) in the glass tube
°C 250
Shutdown temperature (according to prEN 12975-2,
c < 1 m/s) at the collector connection
°C 180
Efficiency
η
0
(according to 12975)
%
78
±
3%
Efficiency coefficient k
1
W/(m
2
•K)
1,09
±
0,2
Efficiency coefficient k
2
W/(m
2
•K
2
)
0,01
±
0,002
Table 4.1 Technical data, auroTHERM exclusive tube collectors
0
0%
10%
20%
30%
40%
50%
60%
70%
80%
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
Δ
T = T
Collector
- T
Ambient air
[K]
Efficiency
η
Fig. 4.3 Efficiency of auroTHERM collector with radiation ener-
gy content of 300 W/m
2
4 Description of the components
Содержание auroTHERM VFK 900
Страница 64: ...71 Manual Solar hot water systems 0020009607_02 Start up protocol 11 ...
Страница 65: ...Manual Solar hot water systems 0020009607_02 72 11 Start up protocol ...
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ...0020009607_02 GB 072008 ...