34

Installer's Quick Guide - aroTHERM plus 11/2020

34

Back to main menu 

Accessories

Description

Article number

aroTHERM plus with heat pump interface 

aroTHERM plus 3.5kW - VWL 35 / 6

0010037211

aroTHERM plus 5kW - VWL 55 / 6

0010037212

aroTHERM plus 7kW - VWL 75 / 6

0010037213

aroTHERM plus 10kW - VWL 105 / 6

0010037214

aroTHERM plus 12kW - VWL 125 / 6

0010037215

aroTHERM plus with hydraulic module

aroTHERM plus 3.5kW - VWL 35 / 6

0010037206

aroTHERM plus 5kW - VWL 55 / 6

0010037207

aroTHERM plus 7kW - VWL 75 / 6

0010037208

aroTHERM plus 10kW - VWL 105 / 6

0010037209

aroTHERM plus 12kW - VWL 125 / 6

0010037210

aroTHERM plus with uniTOWER

aroTHERM plus 3.5kW - VWL 35 / 6

0010037201

aroTHERM plus 5kW - VWL 55 / 6

0010037202

aroTHERM plus 7kW - VWL 75 / 6

0010037203

aroTHERM plus 10kW - VWL 105 / 6

0010037204

aroTHERM plus 12kW - VWL 125 / 6

0010037205

uniSTOR cylinders

150 litre pre-plumbed slimline 

uniSTOR

0020237129

200 litre pre-plumbed uniSTOR

0020237130

250 litre pre-plumbed uniSTOR

0020237131

300 litre pre-plumbed uniSTOR

0020237132

150 litre standard uniSTOR

0020235271

200 litre standard uniSTOR

0020235272

250 litre standard uniSTOR

0020235273

300 litre standard uniSTOR

0020235274

500 litre large capacity uniSTOR

0010019228

800 litre large capacity uniSTOR

0010019229

500 litre large capacity auroSTOR*

0010019234

Accessories

 

Article number

aroTHERM connection kit for ground install 

0010027971

aroTHERM connection kit for ground install 

extension

0010027972

aroTHERM connection kit for wall install 

0010027974

aroTHERM straight pipe connection kit 

0010027976

750mm flexihose for air-to-water heat pump 

(pair)

 0020165288

Snow Spacer 

0010027984

Wall bracket for insulated wall 

0020250224

Wall bracket for non-insulated wall 

0020250225

Anti-vibration feet large

0020250226

Anti-vibration rubber feet small 

0020252091

Coding resistor active cooling 

0020269259

Discharge vessel 

0020145563

aroTHERM 45 litre buffer 

0010038365

aroTHERM heat exchanger module

0020222285

aroTHERM inline 6kW back-up heater 

0020222286

VR 10 temperature sensor 

306787 

WH40 low-loss header (flow rates up to 3,000 

litres per hour) 

306720 

WH95 low-loss header (flow rates up to 8,000 

litres per hour) 

306721 

VR 32/B eBUS coupler (includes housing)  

0020235465

VR 32 eBUS coupler 

0020139895 

Ball filter valve 28mm

0010038133

uniTOWER accessories

uniTOWER decoupling module (small) 

for 3.5 - 7kW model

0010027982

uniTOWER decoupling module (large)

for 10 and 12kW model

0010027973

uniTOWER 1" adapter connection kit

0020269275

18l Buffer cylinder for uniTOWER

0020269273

uniTOWER multi-zone kit - 1 direct zone

0020170507

uniTOWER extension set - 2 direct zones

0020170509

uniTOWER extension set - 1 mixed zone

0020170508

Circulation set without pump

0020170502

Circulation set with pump

0020170503

2l brine expansion vessel

0010030975

uniTOWER connection kit 

(supplied with uniTOWER) (HP circuit)

 0010027979

On wall connection set 

(supplied with uniTOWER) (10 bar)

0010027981

*One unvented kit and expansion vessel required with each 

cylinder.

Содержание aroTHERM plus

Страница 1: ...Comfort for your home aroTHERM plus Air to water heat pumps aroTHERM plus Installer s Quick Guide...

Страница 2: ...ion The non observance of the instructions delivered with the appliance can lead to malfunctions of the appliance and can result in death or serious injuries Some characteristics of the appliance show...

Страница 3: ...e aroTHERM plus system Choose your system schematic 17 Start with the hydraulic connection 18 Proceed to the power supply and eBUS connection 19 Choose your indoor unit uniTOWER hydraulic module or he...

Страница 4: ...7 3 92 10 8 3 63 3 C 13 9 13 4 12 9 12 1 11 2 0 C 15 2 14 6 14 1 13 2 12 3 2 C 16 15 5 14 9 13 9 13 Plan your work Select the correct aroTHERM plus to fit your needs Performance data When designing a...

Страница 5: ...Guide aroTHERM plus 11 2020 Back to main menu Product dimensions 90 26 122 765 mm 449 mm 1100 mm 3 5kW 5kW 965 mm 7kW 1565 mm 10kW 12kW 185 kg 270 106 740 180 180 477 14 14 133 kg 121 kg G 1 unboxed...

Страница 6: ...20 30 40 50 60 0 5 10 15 Distance from heat pump m Sound pressure level dB A 58 9 52 9 49 4 46 9 44 9 43 3 40 8 38 9 37 3 35 4 49 0 43 0 39 5 37 0 35 0 33 4 30 9 29 0 27 4 25 5 aroTHERM VWL 125 5 230...

Страница 7: ...e perfect space for your installation A quiet space for your installation Whilst the aroTHERM plus has been accredited by Quiet Mark for it s super low noise levels When siting pay consideration to be...

Страница 8: ...drains and openings In the unlikely event of a refrigerant leak the gas needs to be allowed to disperse to stop the risk of the gas igniting Follow the diagrams below to ensure adequate clearance C D...

Страница 9: ...9 Installer s Quick Guide aroTHERM plus 11 2020 9 Back to main menu A vented space for perfect operation Do Don t Operation clearances 0 6m 0 1m 0 5m 0 25m 0 2m 1 m...

Страница 10: ...10 Installer s Quick Guide aroTHERM plus 11 2020 10 Back to main menu Install several aroTHERM plus in one spot quiet vented safe Do Don t 500 mm 500 mm...

Страница 11: ...t point of use uniSTOR Heat Pump pre plumbed cylinder range Storage temperature in cylinder 150 200 250 300 Amount of useable hot water at point of use litres 50o C 200 267 333 400 55o C 225 300 375 4...

Страница 12: ...e for deicing aroTHERM plus Minimum open volume required aroTHERM plus 3 5 and 5kW 15 litres aroTHERM plus 7kW 20 litres aroTHERM plus 10 and 12kW 45 litres System expansion vessel sizing Scan the QR...

Страница 13: ...13 Installer s Quick Guide aroTHERM plus 11 2020 13 Back to main menu Decide on the installation type On the roof On the wall 300 mm On the ground 100 mm 100 mm Soak away should always be used...

Страница 14: ...0027976 Mounting Simple Anti vibration feet large Art No 0020250226 Anti vibration rubber feet small Art No 0020252091 Wall brackets for insulated walls Art No 0020250224 excludes rubber feet Wall bra...

Страница 15: ...o 0010027984 excludes rubber feet Connections kits piping and insulation Simple Wall EPP insulation kit Art No 0010027974 includes short straight flexible hose Snow Floor EPP insulation kit Art No 001...

Страница 16: ...ump chosen depending on the heating load calculation chosen Installation site planned quiet vented safe System temperatures chosen underfloor radiator fan coil Domestic hot water and buffer tank chose...

Страница 17: ...aroTHERM plus 11 2020 17 Back to main menu Scan or click the QR Code to download the aroTHERM plus schematics PDF Choose your system schematic Scan or click QR Code for installation video playlist Wat...

Страница 18: ...ack to main menu work your plan Installing the aroTHERM plus system Start with the hydraulic connection Scan or click QR Code for installation video NOTE use of system filter and de airing is importan...

Страница 19: ...connection Preparation T20 B A N L PE 30 mm 30 mm 40 mm eBUS 230 V Fuse T4A Power supplyconnection 230 V X211 X210 X200 X206 N L1 N L1 L2 L3 230 V 230 V 1 5 x 5 5 If possible e bus and power cable mu...

Страница 20: ...Guide aroTHERM plus 11 2020 20 Back to main menu eBUS connection eBUS X211 X210 X200 X206 N L1 L2 L3 0 6 x 3 5 Fasten cable strain reliefs PH2 Power supply 230 V N L 1 2 3 4 5 1 2 L N L1 L2 L3 N L N X...

Страница 21: ...re cylinder with hydraulic components which can easily provide sufficient hot water for the needs of a family of five including the use of rain showers 693 mm 595 mm 1880 mm 70 70 97 103 70 G G 1 G 1...

Страница 22: ...bar Art No 0010027981 2x ct optional hydraulic accessories for the uniTOWER Select optional hydraulic System separation uniTOWER heat exchanger module supplied with a single zone pump Art No 001002798...

Страница 23: ...mportant note you can use the 18l buffer OR the multizone kits as they fit in the same space at the rear of the uniTOWER Single heating zone Single zone heating with low loss header 1 direct and one m...

Страница 24: ...together with a wall mounted hydraulic station and a wide range of accessories including the uniSTOR heat pump cylinders and buffer tanks B B A C D 350 mm 440 mm 720 mm 39 3 47 51 64 5 G 1 143 207 81...

Страница 25: ...suitable the heat pump interface must be fitted with all the hydraulic components installed separately A B PE N L 230 V Bus VF1 SP1 PE N L 230 V AF DCF DCF AF ME EVU PE N L MA1 PE N L MA2 PE N Auf Zu...

Страница 26: ...de aroTHERM plus 11 2020 26 Back to main menu Connect the system accessories Install the heat exchanger module not for use with uniTOWER 360 500 250 180 180 87 101 40 447 452 40 81 5 81 5 40 20 min 20...

Страница 27: ...at pump 1 A B A Installation heating circuit flow B Installation heating circuit flow 500 400 300 200 100 600 700 800 0 B A 500 1000 1500 2000 2500 3000 2 3 1 A Pressure mbar B Flow rate l hour 1 Posi...

Страница 28: ...65 939 G 1 2 G 1 G 1 G 1 G 1 G 1 G 1 200 154 100 100 580 120 120 733 631 154 888 467 365 939 G 1 2 G 1 G 1 G 1 G 1 G 1 G 1 200 200 100 10 600 373 Installing the 45 litre buffer tank 888 200 200 100 10...

Страница 29: ...29 Installer s Quick Guide aroTHERM plus 11 2020 29 Back to main menu XXXXXXXXX XX XX XXX XXXX 4x G 1 6x 1x 1x G B A D C Flow and return system options 4x G 1 6x 1x 1x G B A D C...

Страница 30: ...installation ground wall roof Dirt filter installed in the return Safety valve installed Expansion vessel installed and connected Filling loop and pressure gauge installed All valves installed in syst...

Страница 31: ...K to confirm Back OK an an n nts ts ts ts ts ts ts s s nent nent ent ts s s fi s fi fi fi fin finis nis nis shed hed ed d hed hed hed hed firm m Have the installation assistants for all system compone...

Страница 32: ...cable communication cable m 50 IP rating IP 15 B Fan power consumption W 40 50 Fan quantity 1 2 Fan air flow maximum m3 h 2 300 5 100 Heating pump power consumption W 2 50 3 87 Heating circuit Heating...

Страница 33: ...12102 EN 14511 LWA A7 W45 dB A 53 58 Sound power EN 12102 EN 14511 LWA A7 W55 dB A 54 55 60 Efficiency Energy efficiency class 35 C A to F A Energy efficiency class 55 C A to F A Combination with uni...

Страница 34: ...tion kit for ground install extension 0010027972 aroTHERM connection kit for wall install 0010027974 aroTHERM straight pipe connection kit 0010027976 750mm flexihose for air to water heat pump pair 00...

Страница 35: ...00 VR 70 VR 91 0020236293 Two wireless heating zones and hot water system VRC 700f VR 70 VR 91f 0020259831 Two wired heating zones and solar thermal hot water system VRC 700 VR 70 VR 11 VR 91 00202598...

Страница 36: ...ORT RF VR 71 VR 92f 0010036827 Three wired heating zones and hot water system sensoCOMFORT VR 71 2x VR 92 0010036823 Three wireless heating zones and hot water system sensoCOMFORT RF VR 71 and 2x VR 9...

Страница 37: ...Notes...

Страница 38: ...Notes...

Страница 39: ...Notes...

Страница 40: ...es For more information Telephone 0345 601 8885 email training vaillant co uk Dedicated state of the art Centres of Excellence Vaillant has training facilities all over the country Our centres have be...

Отзывы: