VSC D 206/4-5
190
Minimum heat input
–
heat-
ing (Q)
5.3 kW
Maximum heat input
–
hot
water (Q)
24.5 kW
Minimum heat input
–
hot
water (Q)
6.4 kW
Technical data
–
Domestic hot water
VSC D 146/4-5
150
VSC D 146/4-5
150 (LL)
VSC D 146/4-5
190
VSC D 206/4-5
150
VSC D 206/4-5
150 (LL)
Specific flow rate (D) (
Δ
T
= 30 K) in accordance with
EN 13203
18.8 l/min
18.8 l/min
19.5 l/min
21.7 l/min
21.7 l/min
Output characteristic fig-
ure in accordance with the
standard DIN 4708 (NL)
1.3
1.3
1.5
1.8
1.8
Continuous flow rate (
Δ
T =
35 K)
394 l/h
394 l/h
394 l/h
591 l/h
591 l/h
Specific flow rate (
Δ
T = 35
K)
16.0 l/min
16.0 l/min
16.0 l/min
24.0 l/min
24.0 l/min
Maximum permissible
pressure
1 MPa
1 MPa
1 MPa
1 MPa
1 MPa
Temperature range
35 … 65
℃
35 … 65
℃
35 … 65
℃
35 … 65
℃
35 … 65
℃
Cylinder capacity
141 l
141 l
188 l
141 l
141 l
VSC D 206/4-5
190
Specific flow rate (D) (
Δ
T
= 30 K) in accordance with
EN 13203
22.9 l/min
Output characteristic fig-
ure in accordance with the
standard DIN 4708 (NL)
2.0
Continuous flow rate (
Δ
T =
35 K)
591 l/h
Specific flow rate (
Δ
T = 35
K)
24.0 l/min
Maximum permissible
pressure
1 MPa
Temperature range
35 … 65
℃
Cylinder capacity
188 l
Technical data
–
General
VSC D 146/4-5
150
VSC D 146/4-5
150 (LL)
VSC D 146/4-5
190
Gas category
Germany
II
2ELL3P
II
2ELL3P
II
2ELL3P
Diameter of the gas pipe
G 3/4 inch
G 3/4 inch
G 3/4 inch
Diameter of the heating pipe
G 3/4 inch
G 3/4 inch
G 3/4 inch
Expansion relief valve connector (min.)
24 mm
24 mm
24 mm
Condensed water discharge pipe (min.)
24 mm
24 mm
24 mm
Gas supply pressure (G20)
2 kPa
2 kPa
2 kPa
Gas supply pressure (G25)
2 kPa
2 kPa
2 kPa
CE number (PIN)
1312CO5870
1312CO5870
1312CO5870
Smoke mass flow in heating mode at P min.
1.5 g/s
1.5 g/s
1.5 g/s
Smoke mass flow in heating mode at P max.
6.4 g/s
6.4 g/s
6.4 g/s
Smoke mass flow in hot water handling mode at P max.
7.3 g/s
7.3 g/s
7.3 g/s