1 Safety

4

Installation and maintenance instructions ecoVIT exclusiv 0020258610_00

Do not use any electrical switches, mains
plugs, doorbells, telephones or other com-
munication systems in the building.

Close the emergency control valve or the
main isolator.

If possible, close the gas isolator cock on
the product.

Warn other occupants in the building by
yelling or banging on doors or walls.

Leave the building immediately and ensure
that others do not enter the building.

Alert the police and fire brigade as soon as
you are outside the building.

Use a telephone outside the building to
inform the emergency service department
of the gas supply company.

1.3.4 Risk of death from leaks if the

product is installed below ground
level

Liquid gas accumulates at floor level. If the
product is installed below ground level, liquid
gas may accumulate at floor level if there
are any leaks. In this case, there is a risk of
explosion.

Make sure that liquid gas cannot escape
from the product or the gas line under any
circumstance.

1.3.5 Risk of death due to blocked or

leaking flue gas routes

Installation errors, damage, tampering, unau-
thorised installation sites or similar can cause
flue gas to escape and result in a risk of pois-
oning.
What to do if you smell flue gas in the prop-
erty:

Open all accessible doors and windows
fully to provide ventilation.

Switch off the product.

Check the flue gas routes in the product
and the flue gas diversions.

1.3.6 Risk of death due to explosive and

flammable materials

Do not use the product in storage rooms
that contain explosive or flammable sub-
stances (such as petrol, paper or paint).

1.3.7 Risk of poisoning caused by

insufficient supply of combustion
air

Conditions

: Open-flued operation

Ensure that the air supply to the product's
installation room is permanently unobstruc-
ted and sufficient in accordance with the
relevant ventilation requirements.

1.3.8 Risk of corrosion damage due to

unsuitable combustion and room air

Sprays, solvents, chlorinated cleaning
agents, paint, adhesives, ammonia com-
pounds, dust or similar substances may lead
to corrosion on the product and in the flue
gas guiding.

Ensure that the supply of combustion air is
always free of fluorine, chlorine, sulphur,
dust, etc.

Ensure that no chemical substances are
stored at the installation site.

Ensure that the combustion air is not
routed through chimneys which have
previously been used with floor-standing
oil-fired boilers, or with other boilers,
which could cause soot to build up in the
chimney.

If you are installing the product in
hairdressing salons, painter's or joiner's
workshops, cleaning businesses or similar
locations, choose a separate installation
room in which the room air is technically
free of chemical substances.

1.3.9 Risk of death from electric shock

There is a risk of death from electric shock if
you touch live components.
Before commencing work on the product:

Disconnect the product from the power
supply by switching off all power supplies
at all poles (electrical partition with a con-
tact gap of at least 3 mm, e.g. fuse or cir-
cuit breaker).

Secure against being switched back on
again.

Check that there is no voltage.

Содержание 0010007508

Страница 1: ...nd maintenance instructions ecoVIT exclusiv VKK 226 4 VKK 656 4 AT DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de w...

Страница 2: ...installation 17 7 7 Purging the heating installation 18 7 8 Filling the condensate siphon 18 7 9 Checking the gas setting 18 7 10 Checking the heating mode 20 7 11 Checking the hot water generation 2...

Страница 3: ...t and system approval compliance with all inspection and main tenance conditions listed in the instruc tions Intended use also covers installation in ac cordance with the IP class Any other use that i...

Страница 4: ...e and flammable materials Do not use the product in storage rooms that contain explosive or flammable sub stances such as petrol paper or paint 1 3 7 Risk of poisoning caused by insufficient supply of...

Страница 5: ...tional and inter national laws standards and guidelines 1 3 14 Risk of being burned or scalded by hot components Only carry out work on these components once they have cooled down 1 3 15 Risk of death...

Страница 6: ...0010007508 VKK 226 4 L 0010007688 VKK 286 4 H 0010007512 VKK 286 4 L 0010007692 VKK 366 4 H 0010007516 VKK 366 4 L 0010007696 VKK 476 4 H 0010007520 VKK 476 4 L 0010007700 VKK 656 4 H 0010007524 VKK 6...

Страница 7: ...max e g 85 C Max flow temperature 230 V 50 Hz Electric connection e g 110 W Max electrical power consumption Class I Electrical protection class IP e g X4D IP rating Heating mode P Nominal heat output...

Страница 8: ...environmental temperatures of approx 4 C to approx 50 C Note When selecting the installation site take into con sideration the product s weight when it is ready for operation including the water cont...

Страница 9: ...red to connect a con densate pump The drain must be visible 4 7 Aligning the product Use the height adjustable feet to adjust the product ho rizontally in order to ensure that the condensate drains fr...

Страница 10: ...can cause leaks Install the connection cables so that they are free from mechanical stress Caution Risk of material damage due to heat trans fer during soldering Only solder connectors if the connecto...

Страница 11: ...asuring points 5 3 Information on liquid gas operation In the as delivered condition the product is preset for opera tion with the gas group indicated on the identification plate If you have a product...

Страница 12: ...urn to the heating return con nection 3 4 If you do not connect a domestic hot water cylinder use the enclosed sealing plug to seal the connection 2 5 7 2 Connecting the domestic hot water cylinder re...

Страница 13: ...main switch is switched off Switch off the power supply Secure the power supply against being switched back on again Caution Risk of material damage caused by mal function If cables are routed directl...

Страница 14: ...n Risk of material damage due to high con nected voltage At mains voltages greater than 253 V elec tronic components may be damaged Make sure that the rated voltage of the mains is 220 V Caution Risk...

Страница 15: ...plug connect the contacts in series and not in parallel Close the electronics box Page 13 5 9 5 Connecting the domestic hot water cylinder 3 1 2 1 Connect the cylinder temperature sensor 3 and if req...

Страница 16: ...ist Commissioning checklist Page 37 7 2 Calling up the check programmes 1 Press and hold the button and at the same time briefly press the Reset button Only release the but ton once P 00 is shown in t...

Страница 17: ...the heating water is treated with unsuitable additives Unsuitable additives may cause changes in the components noises in heating mode and possibly subsequent damage Do not use any unsuitable frost a...

Страница 18: ...s 7 8 Filling the condensate siphon Danger Risk of poisoning from escaping flue gas An empty or insufficiently filled condensate siphon may allow flue gas to escape into the room air Fill the condensa...

Страница 19: ...ffers from gas flow pressure by more than 1 0 kPa 10 mbar Caution Risk of material damage and operating faults caused by incorrect gas connec tion pressure If the gas connection pressure lies outside...

Страница 20: ...ot water temperature set the domestic hot water temperature on the boiler to the maximum possible temperature Adjust the target temperature for the connected do mestic hot water cylinder to the contro...

Страница 21: ...e pump overrun for a cylinder charging pump that is directly connected to the product under D 72 If the cylinder charging pump is connected to a VRC 630 or auroMATIC 620 control set the overrun time o...

Страница 22: ...ge 32 Eliminate the fault To restart the product press the reset button Operat ing instructions If you are unable to eliminate the fault and the fault re curs despite several reset attempts contact Va...

Страница 23: ...oduct from the power grid 2 Close the gas stopcock 3 Hinge the electronics box down Page 9 4 Remove the upper casing Page 9 5 Unscrew the locking plate from the ignition electrode and pull out the ign...

Страница 24: ...ace a new seal into the brass nipple on the underside of the gas valve assembly 6 Screw the gas pipe to the underside of the gas valve assembly again Torque 25 Nm 7 Plug the pressure measuring hose in...

Страница 25: ...installation Page 17 2 Purge the heating installation Page 18 3 Check that all control regulation and monitoring devices are functioning properly 4 Check the gas pipe and the heating circuit for tigh...

Страница 26: ...ton Pump off i button Back Check fan i button Yes button Next button Back Fan is actuated at max rotational speed button Fan on button Fan off i button Back Check charging pump i button Yes button Nex...

Страница 27: ...value or return target value Current target value calculated from the set value control control type etc Not ad justable D 007 Cylinder temperature tar get value Current value Only products with no i...

Страница 28: ...Not ad justable D 025 Ext eBUS signal Cylinder charging Current value Hot water generation enabled by eBUS control 0 Off 1 On Not ad justable D 026 Auxiliary relay 1 6 Internal accessory relay at X6 p...

Страница 29: ...ng switch off sequences Current value Number of switch off sequences caused by the air monitoring Not ad justable D 064 Avg ignition time Current value s Not ad justable D 065 Max ignition time Curren...

Страница 30: ...s Current value Number of burner starts x 100 Not ad justable D 084 Maintenance in 0 3000 h Number of hours until the next maintenance 1 300 corresponds to 3000 hrs Deactivated D 087 Set the type of g...

Страница 31: ...ter mode is activated S 27 DHW mode Pump over run The pump overrun for domestic hot water mode is activated S 28 DHW anti cycling time The anti cycling time for domestic hot water mode is activated S...

Страница 32: ...29 Operating failure Ignit unsuccessful Gas supply interrupted intermit tently Re ignition failed Check Flue gas recirculation condensate route blockage earthing cable to the gas valve assembly and el...

Страница 33: ...defect ive Check the fuse on the PCB in the electronics box 1 Replace the fuse No response to the control de mand No eBUS connection Check the connection between the BUS connections in the control and...

Страница 34: ...1 4 3 2 1 13 1 9 6 X2 19 20 21 17 3 1 4 18 8 5 22 C1 C2 Burner Off BUS X1 X18 X1 24V 230V L N X13 X11 L N 1 2 3 3 4 5 X14 L N WH BK BU RD VT GN RD BK BK OG BK BK BK BK BK BK BK BK RD RD BU RD WH BU BU...

Страница 35: ...k characteristic 19 Water pressure sensor 20 actoSTOR sensor 2 7 k characteristic 21 Coding resistor power 5110 22 Gas valve assembly 23 VR 40 230 V power supply 24 Cylinder charging pump 25 Internal...

Страница 36: ...Tel BUS DCF 0 C1 C2 VRC 630 230 V 5 V 24 V 9 8 7 I N Auf Zu 2 1 Zu N Auf N L N L N L N L N L N L N L N L N L N L 1 1 2 1 2 1 2 2 230 V 2 aus 7 Netz 3 1 2 11 4 5 10 6 7 8 9 14 13 12 16 15 17 1 2 in 7...

Страница 37: ...O content Annually 10 Checking the product for tightness in the gas flue gas domestic hot wa ter and condensate pipework Annually 11 Checking all the safety devices Annually 12 Checking and if require...

Страница 38: ...unit categories II2ELL3P DE II2H3P AT II2ELL3P DE II2H3P AT II2ELL3P DE II2H3P AT II2ELL3P DE II2H3P AT II2ELL3P DE II2H3P AT II2ELL3P DE II2H3P AT Gas connection boiler side R 3 4 inch R 3 4 inch R 3...

Страница 39: ...691 mm Approx net weight 100 kg 100 kg 100 kg 100 kg 110 kg 110 kg Ready for operation weight approx 210 kg 210 kg 235 kg 235 kg 255 kg 255 kg VKK 476 4 H VKK 476 4 L VKK 656 4 H VKK 656 4 L Designate...

Страница 40: ...ht 120 kg 120 kg 120 kg 120 kg Ready for operation weight approx 320 kg 320 kg 320 kg 320 kg Technical data Power load G20 VKK 226 4 H VKK 286 4 H VKK 366 4 H VKK 476 4 H VKK 656 4 H Nominal heat outp...

Страница 41: ...g side 45 0 kW 45 0 kW 62 0 kW 62 0 kW Minimum heat input 20 2 kW 20 2 kW 21 7 kW 21 7 kW Technical data Heating VKK 226 4 H VKK 226 4 L VKK 286 4 H VKK 286 4 L VKK 366 4 H VKK 366 4 L Max flow temper...

Страница 42: ...sumption 45 W 45 W 45 W 45 W 45 W 45 W Standby electrical power consumption 6 W 6 W 6 W 6 W 6 W 6 W IP rating IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 Unit protection class Class I Class I Class I Class I...

Страница 43: ...m 21 Flue gas route 4 Front casing 10 Front casing closed 5 Front flap 9 Frost 5 Function check 23 Function menu 23 26 G Gas connection 11 Gas conversion 18 Gas ratio setting 18 H Handing the product...

Страница 44: ...8 0 Telefax 021 91 18 2810 Auftragsannahme Vaillant Kundendienst 021 91 5767901 info vaillant de www vaillant de These instructions or parts thereof are protected by copyright and may be reproduced or...

Отзывы: