3
-
1/2
–
R1 output (Filtration)
-
3/4
–
R2 output (Dosing) / (Attraction2)
-
5/6
–
R3 output (Lights)
-
7/8
–
R4 output (Heating/Cooling)
-
9/10
–
R5 output (Attraction)
4.
Electrical connection
DIN module
-
RS485
–
Communication cable
(connection to dosing unit)
-
Temperature sensor
D
–
( data / green wire)
+
–
(+3,3 V / brown wire)
-
–
( 0,0 V / black or blue wire)
-
Power supply
N
–
neutral wire
L
–
phase wire 230 V
IMPORTANT
:
The temperature sensor must be connected, otherwise the DIN Module will not function properly (heating activation,
dosing, operating protections, etc.).
Pre-set relay outputs
Note:
The relay connection and suppression of their inductive load diagram is in Section 8, page 11..
5.
Pairing the DIN and RC modules
To establish a radio communication between Din and RC modules, both units need to be paired. Required
for pairing is the DIN module serial number
–
simply input the last 4 digits into the RC module. The DIN
S/N is located on the side label of the DIN module; alternatively, also under the DIN microchip cover.
To access the pairing mode, take the turned-off RC module, press and hold the
“F1“
button and
press
the
“ “ button for at least 3 seconds. The display will light up and „0000“ will be displayed.
a)
Using the “
V
“
or
“
ꓥ
“ buttons, select the desired
number,
b)
Press “
<>
“
to move to the next digit,
c)
Press “
SET/SEND
“ to confirm changes a
nd pair the
device. The display will switch to normal screen.
VÁGNER POOL s.r.o.
DIN Module
S/N: DN18MO11
0022
100-250VAC/50-60Hz
Max. 12W
RS485
1 2 3 4 5 6 7 8 9 10
0000
0022
Содержание VArio DIN module
Страница 1: ...1 20 02_ver 1 11_VA SYST M ZEN BAZ NOV TECHNOLOGIE RC modul d lkov ovl d n CZ EN DE HR...
Страница 17: ...19 08_ver 1 11_VA POOL TECHNOLOGY CONTROL SYSTEM RC Module remote control...
Страница 33: ...1 19 08_ver 1 11 SCHWIMMBADTECHNIK STEUERANLAGE RC Modul Fernbedienung...
Страница 49: ...1 19 08_ver 1 11_VA SUSTAV UPRAVLJANJA BAZENSKOM TEHNOLOGIJOM RC modul daljinsko upravljanje...